LWBE3G280-102NS-16 product photo
LWBE3G280-102NS-16 product photo
LWBE3G280-102NS-16 product photo
  • ImpellerØ280 mm11.0 in
  • Max airflow3,193 m³/h1,879 CFM
  • Max static pressure1,442 Pa5.79 in. wg
  • Voltage230 V
  • Speed3,000 rpm
  • Input power500 W
  • Noise75 dB(A)

LWBE3G280-102NS-16 EC Backward Curved Centrifugal Fan Ø280 mm

Ø280 mm | EC | Max airflow 3,193 m³/h | Max static pressure 1,442 Pa | 75 dB(A)

  • Factory direct
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 18-month warranty
  • CE · ETL · RoHS
View RFQ →
Engineering files (on request)

CAD files exist for this model and can be released for assembly checks in SolidWorks / CATIA / Creo / Inventor.

CAD models contain the blade geometry and are not downloadable. Tell us the project; an engineer sends the file after a short check, normally within 1 business day.

Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWBE3G280-102NS-16 Dimensional drawing
Wiring diagramLead colours and terminal assignment; TK = motor thermal contact.
LWBE3G280-102NS-16 Wiring diagram

Downloads for LWBE3G280-102NS-16

PDFDatasheetPDFDrawing · 1002 KB

Need a non-standard size or another format? Ask an engineer or search the download center.

LWBE3G280-102NS-16 is a LONGWELL EC Backward Curved Centrifugal Fan from the Backward Curved Centrifugal Fans range, impeller Ø280 mm, rated 230 V EC, maximum airflow 3,193 m³/h, maximum static pressure 1,442 Pa, noise 75 dB(A), input power 500 W. The EC motor integrates the drive electronics: stepless speed control by 0–10 V or PWM signal, speed feedback and high efficiency at part load.

Technical data

Model LWBE3G280-102NS-16
Series LWBE3G280
Motor type EC
Phase 1-phase
Rated voltage 230 V
Frequency 50 Hz
Current 2.3 A
Input power 500 W
Speed 3,000 rpm
Max. airflow 3,193 m³/h
Max. airflow (CFM) 1,878 CFM
Max. static pressure 1,442 Pa
Noise 75 dB(A)
Ambient temperature -25 ~ 60 °C
Impeller diameter Ø280 mm
Rotor diameter 102
Impeller material Aluminum Alloy
Protection class IP55
Insulation class F
Bearing Maintenance-free ball bearings
Duty S1
Vibration standard JB/T 8689
Rotation Clockwise,seen on rotor

Typical applications

  • Air handling units (AHU) and rooftop units (RTU)
  • Data-center CRAH / CRAC units and fan walls
  • Dust extraction and process ventilation
  • Fan filter units and air purifiers

Series LWBE3G280: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.

Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.

Alternatives with the same impeller (Ø280 mm · EC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWBE3G280-102NS-16 this model 3,193 m³/h1,442 Pa 3,000 rpm500 W75 dB(A)230 V
LWBE3G280-092PS-14 1,743 m³/h481 Pa 2,200 rpm105 W69 dB(A)230 V View
LWBE3G280-092PS-15 1,813 m³/h680 Pa 2,600 rpm165 W74 dB(A)230 V View
LWFE3G280-092PS-03 2,008.5 m³/h803.4 Pa 2,650 rpm225 W70 dB(A)230 V View
LWBE3G280-092PS-13 2,019 m³/h546 Pa 2,200 rpm180 W72 dB(A)230 V View
LWFE3G280-072PS-01 2,317.5 m³/h556.2 Pa 1,910 rpm170 W73 dB(A)230 V View
LWBE3G280-102PS-16 2,318 m³/h824 Pa 2,760 rpm340 W78 dB(A)230 V View
LWBE3G280-102PS-18 2,472 m³/h1,051 Pa 3,100 rpm475 W82 dB(A)230 V View
LWBE3G280-138PT-05 3,028 m³/h886 Pa 3,000 rpm860 W85 dB(A)400 V View
LWBE3G280-102PS-19 3,039 m³/h1,102 Pa 3,000 rpm625 W82 dB(A)230 V View
LWFE3G280-102PS-07 3,193 m³/h1,442 Pa 3,000 rpm500 W75 dB(A)230 V View
LWBE3G280-138PT-06 3,790 m³/h1,421 Pa 3,500 rpm1,355 W89 dB(A)400 V View
LWBE3G280-138NT-18 3,790 m³/h1,421 Pa 3,500 rpm1,355 W89 dB(A)400 V View
LWFE3G280-102PS-04 3,862.5 m³/h1,658 Pa 3,270 rpm700 W85 dB(A)230 V View
LWFE3G280-102PT-08 4,377.5 m³/h1,751 Pa 3,370 rpm1,100 W78 dB(A)400 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Other models in the LWBE3G280 seriesSame impeller, different speed grade or wiring

Adjacent sizesOne size up when airflow is short, one size down when it is too much

Alternatives at a similar dutySimilar airflow, different construction or motor platform

See all Backward Curved Centrifugal Fans  ·  select by duty point

Scroll to Top