Centrifugal Fans

Filter by duty point614 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWFE3G175-072PS-05 LWFE3G175-072PS-05EC Ø175 mm 700.4 875.5 155 75 4,800 230 Details
LWFE3G180-092DS-02 LWFE3G180-092DS-02EC Ø180 mm 1,730 247 165 63 1,090 230 Details
LWFE3G180-092SS-01 LWFE3G180-092SS-01EC Ø180 mm 948 639 240 68 1,650 230 Details
LWFE3G180-092SS-02 LWFE3G180-092SS-02EC Ø180 mm 927 824 220 68 2,200 230 Details
LWFE3G180-102DS-01 LWFE3G180-102DS-01EC Ø180 mm 2,060 742 400 74 1,550 230 Details
LWFE3G190-072PS-01 LWFE3G190-072PS-01EC Ø190 mm 813.7 587.1 87 70 3,300 230 Details
LWFE3G190-072PS-02 LWFE3G190-072PS-02EC Ø190 mm 854.9 875.5 115 71 3,800 230 Details
LWFE3G190-072PS-03 LWFE3G190-072PS-03EC Ø190 mm 973.35 1,009.4 170 72 4,100 230 Details
LWFE3G190-072PS-06 LWFE3G190-072PS-06EC Ø190 mm 638.6 453.2 64 65 2,940 230 Details
LWFE3G190-072PS-07 LWFE3G190-072PS-07EC Ø190 mm 854.9 803.4 135 70 3,700 230 Details
LWFE3G200-102DS-01 LWFE3G200-102DS-01EC Ø200 mm 2,060 1,030 300 64 1,150 230 Details
LWFE3G200-102DS-02 LWFE3G200-102DS-02EC Ø200 mm 2,575 464 390 66 1,300 230 Details
LWFE3G200-102SS-01 LWFE3G200-102SS-01EC Ø200 mm 1,638 700 510 73 1,800 230 Details
LWFE3G220-072PS-01 LWFE3G220-072PS-01EC Ø220 mm 937.3 721 86 68 2,470 230 Details
LWFE3G220-072PS-02 LWFE3G220-072PS-02EC Ø220 mm 1,019.7 597.4 115 69 2,800 230 Details
LWFE3G220-072PS-03 LWFE3G220-072PS-03EC Ø220 mm 1,184.5 978.5 168 70 3,250 230 Details
LWFE3G225-072PS-01 LWFE3G225-072PS-01EC Ø225 mm 1,009.4 618 85 65 2,300 230 Details
LWFE3G225-072PS-02 LWFE3G225-072PS-02EC Ø225 mm 1,184.5 669.5 115 67 2,600 230 Details
LWFE3G225-072PS-03 LWFE3G225-072PS-03EC Ø225 mm 1,313.25 1,030 170 70 3,100 230 Details
LWFE3G225-092PS-04 LWFE3G225-092PS-04EC Ø225 mm 1,359.6 906.4 230 71 3,600 230 Details
LWFE3G225-102DS-02 LWFE3G225-102DS-02EC Ø225 mm 3,039 484 450 68 1,300 230 Details
LWFE3G225-102SS-01 LWFE3G225-102SS-01EC Ø225 mm 1,648 711 505 77 1,500 230 Details
LWFE3G225-138DS-01 LWFE3G225-138DS-01EC Ø225 mm 3,605 577 1,050 78 1,450 380 Details
LWFE3G225-138DS-03 LWFE3G225-138DS-03EC Ø225 mm 3,502 371 750 77 1,250 230 Details
LWFE3G250-072PS-01 LWFE3G250-072PS-01EC Ø250 mm 1,184.5 618 85 62 1,810 230 Details
LWFE3G250-072PS-02 LWFE3G250-072PS-02EC Ø250 mm 1,236 515 115 62 2,180 230 Details
LWFE3G250-072PS-04 LWFE3G250-072PS-04EC Ø250 mm 1,478.05 927 169 71 2,570 230 Details
LWFE3G250-092PS-05 LWFE3G250-092PS-05EC Ø250 mm 1,648 721 230 71 2,700 230 Details
LWFE3G250-102PS-06 LWFE3G250-102PS-06EC Ø250 mm 2,472 1,545 520 85 3,650 230 Details
LWFE3G250-102PS-07 LWFE3G250-102PS-07EC Ø250 mm 3,038.5 1,442 750 93 4,100 230 Details
LWFE3G250-102PT-08 LWFE3G250-102PT-08EC Ø250 mm 3,708 1,751 1,000 92 3,860 400 Details
LWFE3G250-102SS-01 LWFE3G250-102SS-01EC Ø250 mm 1,957 422 500 78 1,320 230 Details
LWFE3G250-138DS-01 LWFE3G250-138DS-01EC Ø250 mm 3,811 742 655 74 920 380 Details
LWFE3G250-138DS-02 LWFE3G250-138DS-02EC Ø250 mm 4,058 479 750 75 960 230 Details
LWFE3G280-072PS-01 LWFE3G280-072PS-01EC Ø280 mm 2,317.5 556.2 170 73 1,910 230 Details
LWFE3G280-092PS-03 LWFE3G280-092PS-03EC Ø280 mm 2,008.5 803.4 225 70 2,650 230 Details
LWFE3G280-102PS-04 LWFE3G280-102PS-04EC Ø280 mm 3,862.5 1,658 700 85 3,270 230 Details
LWFE3G280-102PS-07 LWFE3G280-102PS-07EC Ø280 mm 3,193 1,442 500 75 3,000 230 Details
LWFE3G280-102PT-08 LWFE3G280-102PT-08EC Ø280 mm 4,377.5 1,751 1,100 78 3,370 400 Details
LWFE3G280-138DS-01 LWFE3G280-138DS-01EC Ø280 mm 4,223 917 600 72 800 380 Details
Certifications for this product line
CE-LVD ×3ETL ×2CE-EMCRoHS ×3
View certificates →

Centrifugal Fans — selection guide

Centrifugal Fans: 614 models, impellers Ø108–630 mm, maximum airflow 155–23,896 m³/h, static pressure to 5,401 Pa, EC, AC and DC motors, across 137 series. 525 of them carry a measured P-Q curve and 572 a dimensional drawing.

LONGWELL's centrifugal range is organised by impeller type rather than by application, because the impeller decides the shape of the curve. Backward curved impellers (LWBE3G EC, LWBA AC, LWBD3G DC) hold the high-pressure end and are non-overloading; forward curved multi-vane impellers (LWFE3G EC, LWFA AC, LWFD3G DC) give more airflow per diameter at low pressure; and plug fans are backward curved impellers supplied without a scroll for plenum mounting. The whole family shares the same motor platforms — rotor sizes 92, 102 and 138 on external-rotor motors — so a duty point can usually be met by more than one impeller type, and the selector shows them side by side.

Impeller material follows size: PA66 or PA66-GF up to about Ø225 mm, aluminium alloy from Ø250 mm and galvanised steel for the scroll housings. Supply voltages run from 24 / 48 V DC through 115 / 230 V single-phase to 380 / 400 V three-phase, which is why the same duty can be quoted for a battery-powered unit, a European AHU and a North American rooftop unit.

How to select from this range

  1. Fix the duty point first: airflow plus the static pressure of the whole system at that airflow, including dirty-filter allowance. Nameplate maximum airflow and maximum pressure are two different points on the curve and are never reached together.
  2. Above roughly 300 Pa go backward curved; below that a forward curved blower of the same diameter usually moves more air in a smaller housing.
  3. For AHU plenums and fan walls use plug fans — no scroll, no discharge duct, and EC control as standard.
  4. Pick the motor platform by duty profile: EC for modulating loads and BMS integration (about 30% lower consumption at part load, confirmed against the load profile), AC for constant duty at lowest first cost, DC for 24 / 48 V equipment.
  5. Check the curve margin the selector reports: 10–25% is the target, below 8% is flagged.

Where these fans are used

  • Air handling units and rooftop units
  • Data-center CRAH units and fan walls
  • Dust extraction and fume systems
  • Fan coil units and compact air conditioners
  • Ovens, dryers and process equipment

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Centrifugal Fans

How do backward curved, forward curved and plug fans differ in the LONGWELL range?

Backward curved (LWBE3G / LWBA) impellers give the highest static efficiency and a power curve that falls off at high airflow, so the motor cannot overload. Forward curved (LWFE3G / LWFA / LWFD3G) impellers move more air from a given diameter at low pressure but need a scroll housing. Plug fans are backward curved impellers on an inlet cone without a scroll, for mounting inside a plenum.

Which rotor size should I specify — 92, 102 or 138?

The rotor number is the external-rotor motor size. It fixes the available shaft power and therefore the top of the curve for a given impeller: the same Ø355 impeller is offered on 102 and 138 rotors with different maximum pressure. The selector picks the smallest motor that clears your duty point with margin.

Can one duty point be met by more than one centrifugal type?

Often yes. A 3,000 m³/h at 400 Pa duty can be met by a Ø310 backward curved fan, a Ø280 plug fan or a Ø250 dual-inlet forward blower, with different noise, envelope and efficiency. The selector lists all of them; the choice is then about installation format and control.

Are the centrifugal fans available in 115 V for North America?

Yes. The backward curved and forward curved lines include 115 V single-phase versions, and the DC and EC centrifugal lines carry ETL listing (Intertek control no. 5022563) for UL 507 / CSA C22.2 No. 113.

Related selections

Scroll to Top
RFQ list