Inline Duct Fans

Filter by duty point125 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWDA-200(8")S-PWN-10 LWDA-200(8")S-PWN-10AC Ø200 mm 735 303 113 38 1,650 230 Details
LWDA-200(8")U-PWN-11 LWDA-200(8")U-PWN-11AC Ø200 mm 1,250 435 182 41 2,480 115 Details
LWDA-200(8")U-PWN-12 LWDA-200(8")U-PWN-12AC Ø200 mm 750 302 128 38 1,950 115 Details
LWDA-200S-MBN-13 LWDA-200S-MBN-13AC Ø200 mm 987 515 176 70 2,540 230 Details
LWDA-200S-PWN-14 LWDA-200S-PWN-14AC Ø200 mm 1,236 391 130 29 2,500 230 Details
LWDA-250 (10")S-MWN-02 LWDA-250 (10")S-MWN-02AC Ø250 mm 1,900 see curve 162 68 2,750 220-240 Details
LWDA-250 (10")S-MWN-04 LWDA-250 (10")S-MWN-04AC Ø250 mm 1,900 see curve 162 60 2,750 220-240 Details
LWDA-250 (10")U-MWN-01 LWDA-250 (10")U-MWN-01AC Ø250 mm 1,219 see curve 228 69 3,000 110-120 Details
LWDA-250 (10")U-MWN-03 LWDA-250 (10")U-MWN-03AC Ø250 mm 1,219 see curve 228 62 3,000 110-120 Details
LWDA-250(10")S-MWN-06 LWDA-250(10")S-MWN-06AC Ø250 mm 2,100 215 100 65 2,800 220 Details
LWDA-250(8'')S-PWN-05 LWDA-250(8'')S-PWN-05AC Ø250 mm 1,600 420 175 50 2,500 230 Details
LWDA-250S-MBN-10 LWDA-250S-MBN-10AC Ø250 mm 1,034 515 165 71 2,615 230 Details
LWDA-300 (12")S-MWN-02 LWDA-300 (12")S-MWN-02AC Ø300 mm 3,150 see curve 320 72 2,900 220-240 Details
LWDA-300 (12")S-MWN-04 LWDA-300 (12")S-MWN-04AC Ø300 mm 3,150 see curve 320 65 2,900 220-240 Details
LWDA-300 (12")U-MWN-01 LWDA-300 (12")U-MWN-01AC Ø300 mm 1,900 see curve 489 78 3,450 110-120 Details
LWDA-300 (12")U-MWN-03 LWDA-300 (12")U-MWN-03AC Ø300 mm 1,900 see curve 489 71 3,450 110-120 Details
LWDA-300(12")S-MWN-05 LWDA-300(12")S-MWN-05AC Ø300 mm 3,000 230 120 68 2,800 220 Details
LWDA-315(12.6'')S-PWN-05 LWDA-315(12.6'')S-PWN-05AC Ø315 mm 2,500 450 320 55 2,500 230 Details
LWDA-315S-MBN-02 LWDA-315S-MBN-02AC Ø315 mm 1,680 593 220 80 2,520 230 Details
LWDA-350 (14")S-MWN-02 LWDA-350 (14")S-MWN-02AC Ø350 mm 6,450 see curve 903 79 2,900 220-240 Details
LWDA-350 (14")U-MWN-01 LWDA-350 (14")U-MWN-01AC Ø350 mm 2,130 see curve 260 74 1,720 110-120 Details
LWDA-355 (14")S-MWN-04 LWDA-355 (14")S-MWN-04AC Ø355 mm 6,450 see curve 903 68 2,900 220-240 Details
LWDA-355 (14")U-MWN-03 LWDA-355 (14")U-MWN-03AC Ø355 mm 2,130 see curve 260 63 1,720 110-120 Details
LWDA-400 (16")S-MWN-02 LWDA-400 (16")S-MWN-02AC Ø400 mm 7,100 see curve 1,300 83 2,940 220-240 Details
LWDA-400 (16")S-MWN-04 LWDA-400 (16")S-MWN-04AC Ø400 mm 7,100 see curve 1,300 71 2,940 220-240 Details
LWDA-400 (16")U-MWN-01 LWDA-400 (16")U-MWN-01AC Ø400 mm 2,500 see curve 440 75 1,780 110-120 Details
LWDA-400 (16")U-MWN-03 LWDA-400 (16")U-MWN-03AC Ø400 mm 2,500 see curve 440 66 1,780 110-120 Details
LWDD-100H-MBN-13 LWDD-100H-MBN-13DC Ø100 mm 241 365 30 62 3,000 48 Details
LWDD-100L-MBN-11 LWDD-100L-MBN-11DC Ø100 mm 241 365 30 62 3,000 12 Details
LWDD-100M-MBN-12 LWDD-100M-MBN-12DC Ø100 mm 241 365 30 62 3,000 24 Details
LWDD-125H-MBN-09 LWDD-125H-MBN-09DC Ø125 mm 270 365 32 62 3,000 48 Details
LWDD-125L-MBN-07 LWDD-125L-MBN-07DC Ø125 mm 270 365 32 62 3,000 12 Details
LWDD-125M-MBN-08 LWDD-125M-MBN-08DC Ø125 mm 270 365 32 62 3,000 24 Details
LWDD-160H-MBN-03 LWDD-160H-MBN-03DC Ø160 mm 662 505 100 72 3,050 48 Details
LWDD-160M-MBN-02 LWDD-160M-MBN-02DC Ø160 mm 662 505 100 72 3,050 24 Details
LWDD-200H-MBN-12 LWDD-200H-MBN-12DC Ø200 mm 662 505 60 67 2,600 48 Details
LWDD-200L-MBN-10 LWDD-200L-MBN-10DC Ø200 mm 662 505 60 67 2,600 12 Details
LWDD-200M-MBN-11 LWDD-200M-MBN-11DC Ø200 mm 662 505 60 67 2,600 24 Details
LWDD-250H-MBN-09 LWDD-250H-MBN-09DC Ø250 mm 1,236 577 130 72 2,638 48 Details
LWDD-250M-MBN-08 LWDD-250M-MBN-08DC Ø250 mm 1,236 577 130 72 2,638 24 Details
Certifications for this product line
FCC ×2CE-LVD ×2CE-EMC
View certificates →

Inline Duct Fans — selection guide

Inline Duct Fans: 125 models, impellers Ø98–400 mm, maximum airflow 140–7,100 m³/h, static pressure to 1,030 Pa, AC, EC and DC motors, across 31 series. 49 of them carry a measured P-Q curve and 125 a dimensional drawing.

Inline duct fans install in the run of a round duct from Ø100 to Ø400 mm and are sized by duct diameter first. The range splits into four constructions: metal-cased fans (LWDD / LWDA / LWDE, up to 1,030 Pa) for long or hot runs, plastic-cased fans (LWDA, LWDE3G) for light residential systems, ultra-silent fans with an insulated casing for bedrooms and offices, and mixed flow fans whose diagonal impeller adds centrifugal pressure to axial airflow.

Motor platforms follow the same letters as the rest of the catalogue: LWDA for AC, LWDE for EC and LWDD for 12 / 24 / 48 V DC. Many models are offered as voltage pairs — 110–120 V and 220–240 V — so the same fan can be quoted for 60 Hz and 50 Hz markets.

How to select from this range

  1. Match the nominal size to the duct (100, 125, 150, 160, 200, 250, 315, 355, 400 mm) and then check the duty point — the pressure of the whole run including filters, silencers and grilles.
  2. Long runs, several bends or fine filters call for mixed flow or metal-cased models; short residential runs are fine with plastic-cased fans.
  3. Compare sound levels at the same airflow in the data table rather than by nameplate; a larger fan at lower speed is quieter.
  4. For demand-controlled ventilation choose the EC version (LWDE) with a 0–10 V controller; it runs at the airflow actually needed and cuts consumption by about 30% compared with a fixed-speed fan.
  5. Check the flange type and mounting orientation on the drawing; some metal-cased models are horizontal-only.

Where these fans are used

  • Residential fresh-air and heat-recovery systems
  • Bathroom and kitchen exhaust
  • Office and hotel ventilation
  • Booster duty in long duct runs
  • Grow rooms and small workshops

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Inline Duct Fans

Which duct fan should I use for a Ø150 mm duct?

Any 150-size model in the category: plastic LWDA150 for short residential runs, ultra-silent LWDA / LWDE150 for bedrooms, metal LWDD / LWDE-150 for higher pressure or DC supply, or a mixed flow 150 for a long run. Enter your duty point in the filter bar to see which of them meets it.

What is the difference between the metal and plastic inline fans?

Metal-cased models reach higher pressures (up to about 1,000 Pa) and tolerate higher temperature and continuous duty; plastic-cased models are lighter, corrosion-free and more economical for low-pressure residential systems.

Do the duct fans come with a speed controller?

EC models (LWDE) include 0–10 V / PWM control and can be supplied with a potentiometer or controller; AC models can be paired with a voltage controller or ordered with tapped windings for two speeds.

Are there DC duct fans?

Yes. The metal-cased LWDD line is available in 12 / 24 / 48 V DC for solar, vehicle and telecom installations.

Related selections

Scroll to Top
RFQ list