Plastic Inline Duct Fans
Plastic-cased duct fans: light, corrosion resistant and economical for residential and commercial fresh-air systems. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.
| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWDA-100(4")S-PWN-14AC | Ø100 mm | 325 | 163 | 36 | 30 | 2,360 | 230 | Details |
![]() |
LWDA-100(4")S-PWN-15AC | Ø100 mm | 205 | 135 | 25 | 24 | 1,900 | 230 | Details |
![]() |
LWDA-100(4")U-PWN-16AC | Ø100 mm | 325 | 163 | 34 | 30 | 2,360 | 115 | Details |
![]() |
LWDA-100(4")U-PWN-17AC | Ø100 mm | 205 | 135 | 34 | 24 | 1,900 | 115 | Details |
![]() |
LWDA-125(5")S-PWN-06AC | Ø125 mm | 330 | 168 | 39 | 31 | 2,360 | 230 | Details |
![]() |
LWDA-125(5")S-PWN-07AC | Ø125 mm | 293 | 137 | 28 | 30 | 1,950 | 230 | Details |
![]() |
LWDA-125(5")U-PWN-08AC | Ø125 mm | 330 | 168 | 37 | 31 | 2,360 | 115 | Details |
![]() |
LWDA-125(5")U-PWN-09AC | Ø125 mm | 293 | 137 | 29 | 30 | 1,950 | 115 | Details |
![]() |
LWDA-150(6")S-PWN-11AC | Ø150 mm | 660 | 168 | 59 | 32 | 2,400 | 230 | Details |
![]() |
LWDA-150(6")S-PWN-12AC | Ø150 mm | 530 | 137 | 41 | 30 | 2,050 | 230 | Details |
![]() |
LWDA-150(6")U-PWN-13AC | Ø150 mm | 674 | 355 | 59 | 32 | 2,480 | 115 | Details |
![]() |
LWDA-150(6")U-PWN-14AC | Ø150 mm | 535 | 302 | 44 | 30 | 2,050 | 115 | Details |
![]() |
LWDA-200(8")S-PWN-09AC | Ø200 mm | 910 | 384 | 130 | 40 | 2,300 | 230 | Details |
![]() |
LWDA-200(8")S-PWN-10AC | Ø200 mm | 735 | 303 | 113 | 38 | 1,650 | 230 | Details |
![]() |
LWDA-200(8")U-PWN-11AC | Ø200 mm | 1,250 | 435 | 182 | 41 | 2,480 | 115 | Details |
![]() |
LWDA-200(8")U-PWN-12AC | Ø200 mm | 750 | 302 | 128 | 38 | 1,950 | 115 | Details |
![]() |
LWDA-250(8'')S-PWN-05AC | Ø250 mm | 1,600 | 420 | 175 | 50 | 2,500 | 230 | Details |
![]() |
LWDA-315(12.6'')S-PWN-05AC | Ø315 mm | 2,500 | 450 | 320 | 55 | 2,500 | 230 | Details |
![]() |
LWDE3G100-IS-01EC | Ø98 mm | 385 | 269 | 35 | 28 | 2,800 | 110-240 | Details |
![]() |
LWDE3G100-IS-03EC | Ø98 mm | 385 | 269 | 35 | 28 | 2,800 | 110-240 | Details |
![]() |
LWDE3G150-IS-01EC | Ø147 mm | 705 | 465 | 70 | 34 | 2,800 | 110-240 | Details |
![]() |
LWDE3G150-IS-03EC | Ø147 mm | 705 | 465 | 70 | 34 | 2,800 | 110-240 | Details |
![]() |
LWDE3G200-IS-01EC | Ø198 mm | 1,453 | see curve | 180 | 51 | 3,000 | 110-240 | Details |
![]() |
LWDE3G200-IS-03EC | Ø198 mm | 1,453 | 721 | 180 | 51 | 3,000 | 110-240 | Details |
Plastic Inline Duct Fans — selection guide
Plastic Inline Duct Fans: 24 models, impellers Ø98–315 mm, maximum airflow 205–2,500 m³/h, static pressure to 721 Pa, AC and EC motors, across 9 series. 18 of them carry a measured P-Q curve and 24 a dimensional drawing.
Plastic-cased inline duct fans are the light, economical fans for residential fresh-air and exhaust systems: Ø100 to Ø315 mm, 205–2,500 m³/h at 135–721 Pa, 25–320 W. LWDA models on 230 V and 115 V and the LWDE3G EC models (Ø100 / 150 / 200) on a 110–240 V universal input. Corrosion-free casing, quick-release motor plate on most sizes.
How to select from this range
- Match the duct size, then check the duty point against the filter and grille resistance of a residential run.
- Choose LWDE3G for demand-controlled ventilation on any mains voltage.
- For higher pressure or warm air move to the metal-cased line.
Where these fans are used
- Residential fresh-air systems
- Bathroom and kitchen exhaust
- Small offices and shops
Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — Plastic Inline Duct Fans
Which plastic duct fans are EC?
LWDE3G100, LWDE3G150 and LWDE3G200 with a 110–240 V universal input and 0–10 V control (6 models).
Can the plastic duct fans be mounted in any orientation?
Yes, horizontal or vertical; the drawing shows the bracket and the direction of airflow.