Need a non-standard size or another format? Ask an engineer or search the download center.
Ø100 mm | AC | Max airflow 140 m³/h | Max static pressure 58 Pa | 48 dB(A)

Need a non-standard size or another format? Ask an engineer or search the download center.
LWDA-100(4")S-MWN-08 is a LONGWELL Duct Booster Fan from the Inline Duct Fans range, impeller Ø100 mm, rated 220 V AC, maximum airflow 140 m³/h, maximum static pressure 58 Pa, noise 48 dB(A), input power 20 W. The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.
| Model | LWDA-100(4")S-MWN-08 |
|---|---|
| Series | LWDA100 |
| Motor type | AC |
| Phase | 1-phase |
| Rated voltage | 220 V |
| Frequency | 50 Hz |
| Input power | 20 W |
| Speed | 2,800 rpm |
| Max. airflow | 140 m³/h |
| Max. static pressure | 58 Pa |
| Noise | 48 dB(A) |
| Impeller diameter | Ø100 mm |
| Inlet diameter | 100mm |
Series LWDA100: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWDA-100(4")S-MWN-08 this model | 140 m³/h | 58 Pa | 2,800 rpm | 20 W | 48 dB(A) | 220 V | |
| LWDA-100(4")U-PWN-17 | 205 m³/h | 135 Pa | 1,900 rpm | 34 W | 24 dB(A) | 115 V | View |
| LWDA-100(4")S-PWN-15 | 205 m³/h | 135 Pa | 1,900 rpm | 25 W | 24 dB(A) | 230 V | View |
| LWDA-100S-MBN-14 | 242 m³/h | 326 Pa | 2,450 rpm | 60 W | 59 dB(A) | 230 V | View |
| LWDA-100S-PWN-15 | 319 m³/h | 185 Pa | 2,550 rpm | 40 W | 25 dB(A) | 230 V | View |
| LWDA-100(4")U-PWN-16 | 325 m³/h | 163 Pa | 2,360 rpm | 34 W | 30 dB(A) | 115 V | View |
| LWDA-100(4")S-PWN-14 | 325 m³/h | 163 Pa | 2,360 rpm | 36 W | 30 dB(A) | 230 V | View |
| LWDA-100 (4")U-PWN-01 | 410 m³/h | see curve | 3,350 rpm | 41 W | 52 dB(A) | 110-120 V | View |
| LWDA-100 (4")U-MWN-03 | 410 m³/h | see curve | 3,350 rpm | 41 W | 51 dB(A) | 110-120 V | View |
| LWDA-100 (4")S-PWN-02 | 605 m³/h | 168 Pa | 2,900 rpm | 41 W | 51 dB(A) | 220-240 V | View |
| LWDA-100 (4")S-MWN-04 | 605 m³/h | see curve | 2,900 rpm | 41 W | 49 dB(A) | 220-240 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
LWDA-100S-MBN-14Ø100 mm · 242 m³/h · 326 Pa · ACsame series
LWDA-100 (4")U-MWN-03Ø100 mm · 410 m³/h · ACsame series
LWDA-100 (4")S-MWN-04Ø100 mm · 605 m³/h · ACsame series
LWDA-100 (4")U-PWN-01Ø100 mm · 410 m³/h · ACsame series
LWDA-100 (4")S-PWN-02Ø100 mm · 605 m³/h · 168 Pa · ACsame series
LWDA-100(4")S-PWN-14Ø100 mm · 325 m³/h · 163 Pa · ACsame series
LWDE3G100-IS-01Ø98 mm · 385 m³/h · 269 Pa · ECadjacent size
LWDE3G100-IS-03Ø98 mm · 385 m³/h · 269 Pa · ECadjacent size
LWDD-125M-MBN-08Ø125 mm · 270 m³/h · 365 Pa · DCadjacent size
LWDA-125S-PWN-11Ø125 mm · 319 m³/h · 185 Pa · ACadjacent size
LWDA-125 (5")S-PWN-02Ø125 mm · 605 m³/h · 168 Pa · ACadjacent size
LWDA-125 (5")U-PWN-01Ø125 mm · 410 m³/h · ACadjacent size
LWAD9225LX-0592 mm · 139.8 m³/h · 91 Pa · DCsimilar duty
LWAD9225MX-0592 mm · 139.8 m³/h · 91 Pa · DCsimilar duty
LWAD9225HX-0592 mm · 139.8 m³/h · 91 Pa · DCsimilar duty
LWAE12038SH-04120 mm · 139.1 m³/h · 111.47 Pa · ECsimilar duty
LWDD9-9-ECØ229 mm · 139 m³/h · 587 Pa · ECsimilar duty
LWCD-50250MN-07Ø50 mm · 139 m³/h · 34 Pa · DCsimilar dutySee all Inline Duct Fans · select by duty point