Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.
- ImpellerØ355 mm14.0 in
- Max airflow8,799 m³/h5,179 CFM
- Max static pressure1,102 Pa4.42 in. wg
- Voltage380 V
- Speed760 rpm
- Input power1,700 W2.28 hp
- Noise81 dB(A)
LWFE3G355-188DS-01 EC Dual Inlet Forward Centrifugal Blower Ø355 mm
Ø355 mm | EC | Max airflow 8,799 m³/h | Max static pressure 1,102 Pa | 81 dB(A)
- Factory direct
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 18-month warranty
- CE · ETL · RoHS

Need a non-standard size or another format? Ask an engineer or search the download center.
LWFE3G355-188DS-01 is a LONGWELL EC Dual Inlet Forward Centrifugal Blower from the Dual Inlet Forward Curved Blowers range, impeller Ø355 mm, rated 380 V EC, maximum airflow 8,799 m³/h, maximum static pressure 1,102 Pa, noise 81 dB(A), input power 1,700 W. The EC motor integrates the drive electronics: stepless speed control by 0–10 V or PWM signal, speed feedback and high efficiency at part load.
Technical data
| Model | LWFE3G355-188DS-01 |
|---|---|
| Series | LWFE3G355 |
| Motor type | EC |
| Phase | 3-phase |
| Rated voltage | 380 V |
| Frequency | 50 Hz |
| Current | 3 A |
| Input power | 1,700 W |
| Speed | 760 rpm |
| Max. airflow | 8,799 m³/h |
| Max. static pressure | 1,102 Pa |
| Noise | 81 dB(A) |
| Ambient temperature | -30 ~ 50 °C |
| Impeller diameter | Ø355 mm |
| Rotor diameter | 188 |
| Insulation class | F |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
Typical applications
- Air handling units (AHU) and rooftop units (RTU)
- Data-center CRAH / CRAC units and fan walls
- Dust extraction and process ventilation
- Fan filter units and air purifiers
Series LWFE3G355: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Alternatives with the same impeller (Ø355 mm · EC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWFE3G355-188DS-01 this model | 8,799 m³/h | 1,102 Pa | 760 rpm | 1,700 W | 81 dB(A) | 380 V | |
| LWBE3G355-092PS-15 | 2,472 m³/h | 350 Pa | 1,400 rpm | 120 W | 68 dB(A) | 230 V | View |
| LWBE3G355-102PS-17 | 3,142 m³/h | 670 Pa | 1,900 rpm | 330 W | 77 dB(A) | 230 V | View |
| LWDE-355 (14")U-MWN-03 | 3,467 m³/h | see curve | 2,800 rpm | 659 W | 67 dB(A) | 110-120 V | View |
| LWBE3G355-102PS-16 | 3,554 m³/h | 618 Pa | 1,800 rpm | 285 W | 76 dB(A) | 230 V | View |
| LWBE3G355-102PS-18 | 3,915 m³/h | 770 Pa | 2,050 rpm | 423 W | 74 dB(A) | 230 V | View |
| LWFE3G355-102PS-09 | 4,171.5 m³/h | 906.4 Pa | 2,550 rpm | 520 W | 75 dB(A) | 230 V | View |
| LWFE3G355-102PS-03 | 5,047 m³/h | 1,009.4 Pa | 2,200 rpm | 700 W | 85 dB(A) | 230 V | View |
| LWBE3G355-138PT-20 | 5,356 m³/h | 639 Pa | 2,100 rpm | 990 W | 79 dB(A) | 400 V | View |
| LWFE3G355-102PT-10 | 6,180 m³/h | 1,751 Pa | 2,550 rpm | 1,100 W | 86 dB(A) | 400 V | View |
| LWDE-355 (14")S-MWN-04 | 6,200 m³/h | see curve | 2,800 rpm | 659 W | 67 dB(A) | 220-240 V | View |
| LWBE3G355-138PT-12 | 6,249 m³/h | 1,353 Pa | 2,710 rpm | 1,100 W | 77 dB(A) | 400 V | View |
| LWBE3G355-188PT-26 | 6,756 m³/h | 2,524 Pa | 3,800 rpm | 3,100 W | 96 dB(A) | 380 V | View |
| LWBE3G355-138PT-05 | 7,045 m³/h | 830 Pa | 2,700 rpm | 1,700 W | 81 dB(A) | 400 V | View |
| LWBE3G355-188PT-11 | 8,034 m³/h | 1,545 Pa | 3,200 rpm | 3,090 W | 96 dB(A) | 400 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWFE3G355 seriesSame impeller, different speed grade or wiring
Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWBA4D315-138NT-15Ø315 mm · 2,318 m³/h · 371 Pa · ACadjacent size
LWBA4E315-102NS-18Ø315 mm · 2,079 m³/h · 399 Pa · ACadjacent size
LWBA2D315-188NT-17Ø315 mm · 4,120 m³/h · 1,082 Pa · ACadjacent size
LWBA4D315-138NT-16Ø315 mm · 2,781 m³/h · 515 Pa · ACadjacent size
LWBA4E315-102NS-19Ø315 mm · 1,859 m³/h · 294 Pa · ACadjacent size
LWBA4E315-138NS-13Ø315 mm · 2,318 m³/h · 371 Pa · ACadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWAA4D550S-5MEB-04Ø550 mm · 8,755 m³/h · ACsimilar duty
LWAA4E550S-5MEB-02Ø550 mm · 8,755 m³/h · ACsimilar duty
LWFE3G315-188DS-01Ø315 mm · 8,732 m³/h · 783 Pa · ECsimilar duty
LWEA600S(T)M-070EØ600 mm · 8,700 m³/h · ACsimilar duty
LWEAF600-01Ø600 mm · 8,700 m³/h · ACsimilar duty
LWEX-AF-6A-0.75-4P-3-0018,700 m³/h · ACsimilar dutySee all Centrifugal Fans · select by duty point