Centrifugal Fans

Centrifugal fans for duties that must overcome coils, filters and long duct runs: AHU / RTU, data-center CRAH, dust extraction and process ventilation. The LONGWELL centrifugal platform covers backward curved, forward curved and plug-fan (RLM) constructions on AC / DC / EC motors. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point614 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWBA2D220-092NT-06 LWBA2D220-092NT-06AC Ø220 mm 937 484 85 70 2,500 380 Details
LWBA2D220-092NT-07 LWBA2D220-092NT-07AC Ø220 mm 999 515 100 73 2,700 380 Details
LWBA2D225-092NT-03 LWBA2D225-092NT-03AC Ø225 mm 618 165 45 54 1,420 380 Details
LWBA2D225-092NT-07 LWBA2D225-092NT-07AC Ø225 mm 1,318 788 190 71.8 3,095 380 Details
LWBA2D225-092NT-08 LWBA2D225-092NT-08AC Ø225 mm 1,139 588 119 68.6 2,645 380 Details
LWBA2D225-092NT-11 LWBA2D225-092NT-11AC Ø225 mm 1,133 546 135 74 2,600 380 Details
LWBA2D225-092NT-12 LWBA2D225-092NT-12AC Ø225 mm 1,257 695 180 76 2,900 380 Details
LWBA2D250-092NT-06 LWBA2D250-092NT-06AC Ø250 mm 1,751 721 290 77 2,800 380 Details
LWBA2D250-092NT-10 LWBA2D250-092NT-10AC Ø250 mm 1,288 597 160 74 2,450 380 Details
LWBA2D250-092NT-11 LWBA2D250-092NT-11AC Ø250 mm 1,185 773 185 76 2,600 380 Details
LWBA2D250-092NT-15 LWBA2D250-092NT-15AC Ø250 mm 1,421 618 150 76 2,450 380 Details
LWBA2D250-092NT-16 LWBA2D250-092NT-16AC Ø250 mm 1,499 773 200 79 2,550 380 Details
LWBA2D280-092NT-02 LWBA2D280-092NT-02AC Ø280 mm 1,700 721 200 79 2,500 380 Details
LWBA2D280-102NT-06 LWBA2D280-102NT-06AC Ø280 mm 1,833 773 250 80 2,650 380 Details
LWBA2D280-102NT-08 LWBA2D280-102NT-08AC Ø280 mm 2,163 773 330 80 2,700 380 Details
LWBA2D280-138NT-09 LWBA2D280-138NT-09AC Ø280 mm 2,678 917 500 78 2,750 380 Details
LWBA2D280-138NT-10 LWBA2D280-138NT-10AC Ø280 mm 2,833 927 680 80 2,900 380 Details
LWBA2D315-138NT-12 LWBA2D315-138NT-12AC Ø315 mm 3,605 927 800 84 2,750 380 Details
LWBA2D315-188NT-17 LWBA2D315-188NT-17AC Ø315 mm 4,120 1,082 1,300 85 2,650 380 Details
LWBA2D355-188NT-17 LWBA2D355-188NT-17AC Ø355 mm 4,635 1,339 1,600 90 2,700 380 Details
LWBA2D355-188NT-18 LWBA2D355-188NT-18AC Ø355 mm 5,974 1,339 2,500 90 2,700 380 Details
LWBA2E133-072NS-01 LWBA2E133-072NS-01AC Ø133 mm 245 242 32.2 58.7 3,070 230 Details
LWBA2E133-072NS-02 LWBA2E133-072NS-02AC Ø133 mm 225 184 27.8 57.9 2,720 230 Details
LWBA2E155-092NS-01 LWBA2E155-092NS-01AC Ø155 mm 464 216 32 61 2,650 230 Details
LWBA2E155-092NS-02 LWBA2E155-092NS-02AC Ø155 mm 494 278 38 64 3,000 230 Details
LWBA2E175-072NS-02 LWBA2E175-072NS-02AC Ø175 mm 504 294 36 60.8 2,770 230 Details
LWBA2E175-072NU-01 LWBA2E175-072NU-01AC Ø175 mm 567 368 46.1 61.1 3,060 115 Details
LWBA2E175-092NS-03 LWBA2E175-092NS-03AC Ø175 mm 443 288 52 64 2,500 230 Details
LWBA2E175-092NS-04 LWBA2E175-092NS-04AC Ø175 mm 505 386 66 66 2,700 230 Details
LWBA2E175-092NS-05 LWBA2E175-092NS-05AC Ø175 mm 443 288 52 64 2,530 230 Details
LWBA2E180-092NS-01 LWBA2E180-092NS-01AC Ø180 mm 443 335 52 63 2,550 230 Details
LWBA2E180-092NS-02 LWBA2E180-092NS-02AC Ø180 mm 494 371 66 66 2,850 230 Details
LWBA2E180-092NS-03 LWBA2E180-092NS-03AC Ø180 mm 443 335 52 63 2,560 230 Details
LWBA2E190-072NS-01 LWBA2E190-072NS-01AC Ø190 mm 483 357 56 64.9 2,640 230 Details
LWBA2E190-092NS-03 LWBA2E190-092NS-03AC Ø190 mm 457 368 60 65.2 2,700 230 Details
LWBA2E190-092NU-02 LWBA2E190-092NU-02AC Ø190 mm 536 504 70 68.5 3,080 115 Details
LWBA2E220-092NS-01 LWBA2E220-092NS-01AC Ø220 mm 1,029 662 129 67.1 2,780 230 Details
LWBA2E220-092NS-02 LWBA2E220-092NS-02AC Ø220 mm 945 515 101 66.6 2,530 230 Details
LWBA2E220-092NS-04 LWBA2E220-092NS-04AC Ø220 mm 937 484 90 70 2,500 230 Details
LWBA2E220-092NS-05 LWBA2E220-092NS-05AC Ø220 mm 999 515 100 73 2,700 230 Details
Certifications for this product line
CE-LVD ×3ETL ×2CE-EMCRoHS ×3
View certificates →

Centrifugal Fans — selection guide

Centrifugal Fans: 614 models, impellers Ø108–630 mm, maximum airflow 155–23,896 m³/h, static pressure to 5,401 Pa, EC, AC and DC motors, across 137 series. 525 of them carry a measured P-Q curve and 572 a dimensional drawing.

LONGWELL's centrifugal range is organised by impeller type rather than by application, because the impeller decides the shape of the curve. Backward curved impellers (LWBE3G EC, LWBA AC, LWBD3G DC) hold the high-pressure end and are non-overloading; forward curved multi-vane impellers (LWFE3G EC, LWFA AC, LWFD3G DC) give more airflow per diameter at low pressure; and plug fans are backward curved impellers supplied without a scroll for plenum mounting. The whole family shares the same motor platforms — rotor sizes 92, 102 and 138 on external-rotor motors — so a duty point can usually be met by more than one impeller type, and the selector shows them side by side.

Impeller material follows size: PA66 or PA66-GF up to about Ø225 mm, aluminium alloy from Ø250 mm and galvanised steel for the scroll housings. Supply voltages run from 24 / 48 V DC through 115 / 230 V single-phase to 380 / 400 V three-phase, which is why the same duty can be quoted for a battery-powered unit, a European AHU and a North American rooftop unit.

How to select from this range

  1. Fix the duty point first: airflow plus the static pressure of the whole system at that airflow, including dirty-filter allowance. Nameplate maximum airflow and maximum pressure are two different points on the curve and are never reached together.
  2. Above roughly 300 Pa go backward curved; below that a forward curved blower of the same diameter usually moves more air in a smaller housing.
  3. For AHU plenums and fan walls use plug fans — no scroll, no discharge duct, and EC control as standard.
  4. Pick the motor platform by duty profile: EC for modulating loads and BMS integration (about 30% lower consumption at part load, confirmed against the load profile), AC for constant duty at lowest first cost, DC for 24 / 48 V equipment.
  5. Check the curve margin the selector reports: 10–25% is the target, below 8% is flagged.

Where these fans are used

  • Air handling units and rooftop units
  • Data-center CRAH units and fan walls
  • Dust extraction and fume systems
  • Fan coil units and compact air conditioners
  • Ovens, dryers and process equipment

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Centrifugal Fans

How do backward curved, forward curved and plug fans differ in the LONGWELL range?

Backward curved (LWBE3G / LWBA) impellers give the highest static efficiency and a power curve that falls off at high airflow, so the motor cannot overload. Forward curved (LWFE3G / LWFA / LWFD3G) impellers move more air from a given diameter at low pressure but need a scroll housing. Plug fans are backward curved impellers on an inlet cone without a scroll, for mounting inside a plenum.

Which rotor size should I specify — 92, 102 or 138?

The rotor number is the external-rotor motor size. It fixes the available shaft power and therefore the top of the curve for a given impeller: the same Ø355 impeller is offered on 102 and 138 rotors with different maximum pressure. The selector picks the smallest motor that clears your duty point with margin.

Can one duty point be met by more than one centrifugal type?

Often yes. A 3,000 m³/h at 400 Pa duty can be met by a Ø310 backward curved fan, a Ø280 plug fan or a Ø250 dual-inlet forward blower, with different noise, envelope and efficiency. The selector lists all of them; the choice is then about installation format and control.

Are the centrifugal fans available in 115 V for North America?

Yes. The backward curved and forward curved lines include 115 V single-phase versions, and the DC and EC centrifugal lines carry ETL listing (Intertek control no. 5022563) for UL 507 / CSA C22.2 No. 113.

Related selections

Scroll to Top
RFQ list