Centrifugal Fans

Filter by duty point614 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWBA4E355-102NS-15 LWBA4E355-102NS-15AC Ø355 mm 3,035 546 268 73.8 1,635 230 Details
LWBA4E355-102NS-16 LWBA4E355-102NS-16AC Ø355 mm 2,636 410 203 69.9 1,425 230 Details
LWBA4E355-138NS-13 LWBA4E355-138NS-13AC Ø355 mm 3,399 464 400 72 1,400 230 Details
LWBA4E355-138NS-14 LWBA4E355-138NS-14AC Ø355 mm 4,017 618 600 77 1,700 230 Details
LWBA4E400-102NS-01 LWBA4E400-102NS-01AC Ø400 mm 2,936 464 260 64 1,350 230 Details
LWBA4E400-102NS-02 LWBA4E400-102NS-02AC Ø400 mm 3,090 515 330 68 1,450 230 Details
LWBA4E400-138NS-07 LWBA4E400-138NS-07AC Ø400 mm 4,532 494 550 69 1,380 230 Details
LWBA4E400-138NS-09 LWBA4E400-138NS-09AC Ø400 mm 4,120 494 430 66 1,380 230 Details
LWBA4E450-138NS-02 LWBA4E450-138NS-02AC Ø450 mm 6,077 618 800 76 1,350 230 Details
LWBA6D450-138NT-07 LWBA6D450-138NT-07AC Ø450 mm 4,017 309 300 60 920 380 Details
LWBA6D500-138NT-03 LWBA6D500-138NT-03AC Ø500 mm 5,356 361 450 63 950 380 Details
LWBA6D500-138NT-04 LWBA6D500-138NT-04AC Ø500 mm 5,817 412 550 65 1,050 380 Details
LWBA6D560-188NT-02 LWBA6D560-188NT-02AC Ø560 mm 9,270 464 900 73 910 380 Details
LWBA6D560-188NT-04 LWBA6D560-188NT-04AC Ø560 mm 9,270 464 900 73 910 380 Details
LWBA6D630-188NT-01 LWBA6D630-188NT-01AC Ø630 mm 12,360 494 1,500 80 900 380 Details
LWBA6E315-102NS-07 LWBA6E315-102NS-07AC Ø315 mm 1,030 155 75 58 940 230 Details
LWBA6E315-102NS-08 LWBA6E315-102NS-08AC Ø315 mm 1,133 185 85 60 1,050 230 Details
LWBA6E355-102NS-03 LWBA6E355-102NS-03AC Ø355 mm 1,257 175 100 60 930 230 Details
LWBA6E355-102NS-04 LWBA6E355-102NS-04AC Ø355 mm 1,442 206 130 61 1,080 230 Details
LWBA6E400-102NS-05 LWBA6E400-102NS-05AC Ø400 mm 2,163 216 135 56 940 230 Details
LWBA6E400-102NS-06 LWBA6E400-102NS-06AC Ø400 mm 2,421 278 155 57 1,050 230 Details
LWBA6E450-138NS-05 LWBA6E450-138NS-05AC Ø450 mm 4,017 309 260 60 930 230 Details
LWBA6E450-138NS-06 LWBA6E450-138NS-06AC Ø450 mm 4,450 381 350 61 1,050 230 Details
LWBA8D630-188NT-02 LWBA8D630-188NT-02AC Ø630 mm 9,270 288 700 72 700 380 Details
LWBD3G133-072NH-03 LWBD3G133-072NH-03DC Ø133 mm 386 335 28 65 3,900 48 Details
LWBD3G133-072NM-02 LWBD3G133-072NM-02DC Ø133 mm 386 335 28 65 3,900 24 Details
LWBD3G175-072NH-03 LWBD3G175-072NH-03DC Ø175 mm 618 515 75 71 3,900 48 Details
LWBD3G175-072NM-02 LWBD3G175-072NM-02DC Ø175 mm 618 515 75 71 3,900 24 Details
LWBD3G175-072NM-04 LWBD3G175-072NM-04DC Ø175 mm 670 319 50 68 2,800 24 Details
LWBD3G190-072NH-05 LWBD3G190-072NH-05DC Ø190 mm 731 453 75 70 3,100 48 Details
LWBD3G190-072NM-04 LWBD3G190-072NM-04DC Ø190 mm 731 453 75 70 3,100 24 Details
LWBD3G190-092NH-07 LWBD3G190-092NH-07DC Ø190 mm 505 412 85 73 3,300 48 Details
LWBD3G190-092NM-06 LWBD3G190-092NM-06DC Ø190 mm 505 412 85 73 3,300 24 Details
LWBD3G220-092NH-05 LWBD3G220-092NH-05DC Ø220 mm 1,030 577 110 73 3,100 48 Details
LWBD3G220-092NM-04 LWBD3G220-092NM-04DC Ø220 mm 1,030 577 110 73 3,100 24 Details
LWBD3G225-092NH-05 LWBD3G225-092NH-05DC Ø225 mm 1,092 515 100 72 2,700 48 Details
LWBD3G225-092NH-06 LWBD3G225-092NH-06DC Ø225 mm 1,030 515 100 70 2,700 48 Details
LWBD3G225-092NM-04 LWBD3G225-092NM-04DC Ø225 mm 1,092 515 100 72 2,700 24 Details
LWBD3G250-072NZ-07 LWBD3G250-072NZ-07DC Ø250 mm 1,483 597 110 69 2,800 310 Details
LWBD3G250-092NH-05 LWBD3G250-092NH-05DC Ø250 mm 577 1,009 150 79 3,000 48 Details
Certifications for this product line
CE-LVD ×3ETL ×2CE-EMCRoHS ×3
View certificates →

Centrifugal Fans — selection guide

Centrifugal Fans: 614 models, impellers Ø108–630 mm, maximum airflow 155–23,896 m³/h, static pressure to 2,524 Pa, EC, AC and DC motors, across 137 series. 525 of them carry a measured P-Q curve and 572 a dimensional drawing.

LONGWELL's centrifugal range is organised by impeller type rather than by application, because the impeller decides the shape of the curve. Backward curved impellers (LWBE3G EC, LWBA AC, LWBD3G DC) hold the high-pressure end and are non-overloading; forward curved multi-vane impellers (LWFE3G EC, LWFA AC, LWFD3G DC) give more airflow per diameter at low pressure; and plug fans are backward curved impellers supplied without a scroll for plenum mounting. The whole family shares the same motor platforms — rotor sizes 92, 102 and 138 on external-rotor motors — so a duty point can usually be met by more than one impeller type, and the selector shows them side by side.

Impeller material follows size: PA66 or PA66-GF up to about Ø225 mm, aluminium alloy from Ø250 mm and galvanised steel for the scroll housings. Supply voltages run from 24 / 48 V DC through 115 / 230 V single-phase to 380 / 400 V three-phase, which is why the same duty can be quoted for a battery-powered unit, a European AHU and a North American rooftop unit.

How to select from this range

  1. Fix the duty point first: airflow plus the static pressure of the whole system at that airflow, including dirty-filter allowance. Nameplate maximum airflow and maximum pressure are two different points on the curve and are never reached together.
  2. Above roughly 300 Pa go backward curved; below that a forward curved blower of the same diameter usually moves more air in a smaller housing.
  3. For AHU plenums and fan walls use plug fans — no scroll, no discharge duct, and EC control as standard.
  4. Pick the motor platform by duty profile: EC for modulating loads and BMS integration (about 30% lower consumption at part load, confirmed against the load profile), AC for constant duty at lowest first cost, DC for 24 / 48 V equipment.
  5. Check the curve margin the selector reports: 10–25% is the target, below 8% is flagged.

Where these fans are used

  • Air handling units and rooftop units
  • Data-center CRAH units and fan walls
  • Dust extraction and fume systems
  • Fan coil units and compact air conditioners
  • Ovens, dryers and process equipment

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Centrifugal Fans

How do backward curved, forward curved and plug fans differ in the LONGWELL range?

Backward curved (LWBE3G / LWBA) impellers give the highest static efficiency and a power curve that falls off at high airflow, so the motor cannot overload. Forward curved (LWFE3G / LWFA / LWFD3G) impellers move more air from a given diameter at low pressure but need a scroll housing. Plug fans are backward curved impellers on an inlet cone without a scroll, for mounting inside a plenum.

Which rotor size should I specify — 92, 102 or 138?

The rotor number is the external-rotor motor size. It fixes the available shaft power and therefore the top of the curve for a given impeller: the same Ø355 impeller is offered on 102 and 138 rotors with different maximum pressure. The selector picks the smallest motor that clears your duty point with margin.

Can one duty point be met by more than one centrifugal type?

Often yes. A 3,000 m³/h at 400 Pa duty can be met by a Ø310 backward curved fan, a Ø280 plug fan or a Ø250 dual-inlet forward blower, with different noise, envelope and efficiency. The selector lists all of them; the choice is then about installation format and control.

Are the centrifugal fans available in 115 V for North America?

Yes. The backward curved and forward curved lines include 115 V single-phase versions, and the DC and EC centrifugal lines carry ETL listing (Intertek control no. 5022563) for UL 507 / CSA C22.2 No. 113.