Plug Fans (RLM Plenum Fans)

Plug fans (RLM / plenum fans) run without a scroll housing and mount directly inside the unit plenum — the most integrated format for AHU OEMs and fan-wall (FanGrid) arrays. EC versions accept 0–10 V / PWM speed control. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point111 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWBE3G133-072PS-06 LWBE3G133-072PS-06EC Ø133 mm 473 609 72 68 5,200 230 Details
LWBE3G155-072PS-01 LWBE3G155-072PS-01EC Ø155 mm 433 371 40 63 3,570 230 Details
LWBE3G175-072PS-10 LWBE3G175-072PS-10EC Ø175 mm 924 893 132 69 5,020 230 Details
LWBE3G190-072PS-12 LWBE3G190-072PS-12EC Ø190 mm 851 798 104 70 4,230 230 Details
LWBE3G220-072PS-10 LWBE3G220-072PS-10EC Ø220 mm 886 433 75 71 2,600 230 Details
LWBE3G220-092PS-11 LWBE3G220-092PS-11EC Ø220 mm 989 711 145 75 3,310 230 Details
LWBE3G225-072PS-11 LWBE3G225-072PS-11EC Ø225 mm 1,112 433 80 69 2,500 230 Details
LWBE3G225-092PS-07 LWBE3G225-092PS-07EC Ø225 mm 1,630 839 315 71 3,500 230 Details
LWBE3G225-092PS-12 LWBE3G225-092PS-12EC Ø225 mm 1,528 683 170 71.1 3,060 230 Details
LWBE3G225-092PS-13 LWBE3G225-092PS-13EC Ø225 mm 1,545 731 160 71 3,000 230 Details
LWBE3G250-072PS-15 LWBE3G250-072PS-15EC Ø250 mm 1,215 391 90 68 2,150 230 Details
LWBE3G250-072PS-17 LWBE3G250-072PS-17EC Ø250 mm 1,421 639 140 77 2,760 230 Details
LWBE3G250-092PS-16 LWBE3G250-092PS-16EC Ø250 mm 1,531 785 140 72.1 3,010 230 Details
LWBE3G250-092PS-20 LWBE3G250-092PS-20EC Ø250 mm 1,730 525 145 74 2,500 230 Details
LWBE3G250-092PS-21 LWBE3G250-092PS-21EC Ø250 mm 1,421 556 170 69 2,600 230 Details
LWBE3G250-102PS-22 LWBE3G250-102PS-22EC Ø250 mm 1,524 773 240 78 3,150 230 Details
LWBE3G250-102PS-23 LWBE3G250-102PS-23EC Ø250 mm 1,751 824 270 84 3,170 230 Details
LWBE3G250-102PS-24 LWBE3G250-102PS-24EC Ø250 mm 1,700 1,082 370 82 3,500 230 Details
LWBE3G280-092PS-13 LWBE3G280-092PS-13EC Ø280 mm 2,019 546 180 72 2,200 230 Details
LWBE3G280-092PS-14 LWBE3G280-092PS-14EC Ø280 mm 1,743 481 105 69 2,200 230 Details
LWBE3G280-092PS-15 LWBE3G280-092PS-15EC Ø280 mm 1,813 680 165 74 2,600 230 Details
LWBE3G280-102PS-16 LWBE3G280-102PS-16EC Ø280 mm 2,318 824 340 78 2,760 230 Details
LWBE3G280-102PS-18 LWBE3G280-102PS-18EC Ø280 mm 2,472 1,051 475 82 3,100 230 Details
LWBE3G280-102PS-19 LWBE3G280-102PS-19EC Ø280 mm 3,039 1,102 625 82 3,000 230 Details
LWBE3G280-138PT-05 LWBE3G280-138PT-05EC Ø280 mm 3,028 886 860 85 3,000 400 Details
LWBE3G280-138PT-06 LWBE3G280-138PT-06EC Ø280 mm 3,790 1,421 1,355 89 3,500 400 Details
LWBE3G310-092PS-11 LWBE3G310-092PS-11EC Ø310 mm 2,235 474 160 75 1,850 230 Details
LWBE3G310-092PS-12 LWBE3G310-092PS-12EC Ø310 mm 2,410 443 150 75 1,750 230 Details
LWBE3G310-102PS-02 LWBE3G310-102PS-02EC Ø310 mm 2,869 630 285 70 2,150 230 Details
LWBE3G310-102PS-15 LWBE3G310-102PS-15EC Ø310 mm 2,936 700 370 76 2,300 230 Details
LWBE3G310-102PS-16 LWBE3G310-102PS-16EC Ø310 mm 2,884 963 450 78 2,600 230 Details
LWBE3G310-138PT-04 LWBE3G310-138PT-04EC Ø310 mm 4,398 824 980 74 2,600 400 Details
LWBE3G310-138PT-10 LWBE3G310-138PT-10EC Ø310 mm 5,593 1,082 1,588 92 3,300 400 Details
LWBE3G355-092PS-15 LWBE3G355-092PS-15EC Ø355 mm 2,472 350 120 68 1,400 230 Details
LWBE3G355-102PS-16 LWBE3G355-102PS-16EC Ø355 mm 3,554 618 285 76 1,800 230 Details
LWBE3G355-102PS-17 LWBE3G355-102PS-17EC Ø355 mm 3,142 670 330 77 1,900 230 Details
LWBE3G355-102PS-18 LWBE3G355-102PS-18EC Ø355 mm 3,915 770 423 74 2,050 230 Details
LWBE3G355-138PT-05 LWBE3G355-138PT-05EC Ø355 mm 7,045 830 1,700 81 2,700 400 Details
LWBE3G355-138PT-12 LWBE3G355-138PT-12EC Ø355 mm 6,249 1,353 1,100 77 2,710 400 Details
LWBE3G355-138PT-20 LWBE3G355-138PT-20EC Ø355 mm 5,356 639 990 79 2,100 400 Details
Certifications for this product line
CE-LVD ×3ETL ×2CE-EMCRoHS ×3
View certificates →

Plug Fans (RLM Plenum Fans) — selection guide

Plug Fans (RLM Plenum Fans): 111 models, impellers Ø133–630 mm, maximum airflow 267–23,896 m³/h, static pressure to 2,524 Pa, EC motors, across 26 series. 67 of them carry a measured P-Q curve and 69 a dimensional drawing.

Plug fans (RLM plenum fans) are impellers on an inlet cone without a scroll housing, mounted inside the unit plenum so the air discharges freely — the standard format for AHU OEMs and fan-wall (FanGrid) arrays. All 111 models are EC: LWBE3G backward curved impellers from Ø133 to Ø630 mm and LWFE3G forward curved impellers for the compact sizes, on 230 V single-phase up to Ø355 mm and 400 V three-phase above. Impellers are PA6-GF to Ø225 mm and aluminium alloy from Ø250 mm; IP55 on 43 models.

Because there is no scroll, the fan is rated at static pressure and mounting length is short, which is what makes arrays of four to sixteen units possible in the depth of a single large fan.

How to select from this range

  1. Rate on static pressure — a plug fan does not recover velocity pressure, so compare it with housed blowers on static, not total, pressure.
  2. For fan walls choose several Ø310–450 mm units rather than one Ø630: redundancy, easier handling and lower noise at the same total airflow.
  3. Three-phase 400 V from Ø355 mm upward; 230 V single-phase below.
  4. Allow at least 0.5 × diameter between the inlet cone and the nearest wall or coil.

Where these fans are used

  • AHU supply and return sections
  • FanGrid / fan-wall arrays
  • CRAH and CRAC units
  • Retrofit of belt-driven AHU fans

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Plug Fans (RLM Plenum Fans)

What is the difference between a plug fan and a free-running fan in the code?

P in the model code (LWBE3G355-188PT) is the plug-fan version with inlet cone and mounting plate; N is the free-running impeller for integration into your own inlet ring. Performance is the same impeller; the P version is delivered ready to bolt into the plenum.

How many plug fans go into a fan wall?

Typically 4–16 units of Ø310–500 mm. Send total airflow, static pressure and the section dimensions and we propose the array with N+1 redundancy.

Can plug fans replace a belt-driven AHU fan?

Yes — that is the most common retrofit. The plug fan sits in the same section, removes belts and bearings maintenance and adds speed control; the 2024 European AHU retrofit used LWBE3G450 units at 8,660 m³/h and 2,000+ Pa with about 30% lower consumption.