Air Blowers (Air Knife / Air Pump)
High-speed air blowers for blow-off, drying and air-knife applications that need a concentrated air stream. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.
Browse by size
| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWA-1100-01AC | 43 mm | 1,200 | 2,550 | 1,100 | — | — | 230 | Details |
![]() |
LWA-1100-02AC | 43 mm | 1,200 | 2,650 | 1,100 | — | — | 120 | Details |
![]() |
LWA-1100-03AC | 43 mm | 1,200 | 2,550 | 1,100 | — | — | 230 | Details |
![]() |
LWA-1100-04AC | 43 mm | 1,200 | 2,650 | 1,100 | — | 2,850 | 220-240 | Details |
![]() |
LWA-370-01AC | 37 mm | 750 | 1,500 | 370 | — | — | 230 | Details |
![]() |
LWA-370-02AC | 37 mm | 760 | 1,650 | 370 | — | — | 120 | Details |
![]() |
LWA-370-03AC | 37 mm | 750 | 1,500 | 370 | — | — | 230 | Details |
![]() |
LWA-370-04AC | 37 mm | 760 | 1,500 | 370 | — | 2,850 | 220-240 | Details |
![]() |
LWA-480-01AC | 37 mm | 800 | 1,800 | 480 | — | — | 120 | Details |
![]() |
LWA-550-01AC | 37 mm | 800 | 1,800 | 550 | — | — | 230 | Details |
![]() |
LWA-550-02AC | 37 mm | 850 | 1,900 | 550 | — | — | 120 | Details |
![]() |
LWA-550-03AC | 37 mm | 800 | 1,800 | 550 | — | — | 230 | Details |
![]() |
LWA-550-04AC | 37 mm | 800 | 1,800 | 550 | — | 2,850 | 220-240 | Details |
![]() |
LWA-680-01AC | 43 mm | 850 | 1,950 | 680 | — | — | 230 | Details |
![]() |
LWA-680-02AC | 43 mm | 900 | 2,200 | 680 | — | — | 120 | Details |
![]() |
LWA-680-03AC | 43 mm | 850 | 1,950 | 680 | — | — | 230 | Details |
![]() |
LWA-680-04AC | 43 mm | 850 | 1,950 | 680 | — | 2,850 | 220-240 | Details |
![]() |
LWA-750-01AC | 43 mm | 900 | 2,200 | 750 | — | — | 230 | Details |
![]() |
LWA-750-02AC | 43 mm | 960 | 2,550 | 750 | — | — | 120 | Details |
![]() |
LWA-750-03AC | 43 mm | 900 | 2,200 | 750 | — | — | 230 | Details |
![]() |
LWA-750-04AC | 43 mm | 900 | 2,550 | 750 | — | 2,850 | 220-240 | Details |
![]() |
LWA-950-01AC | 43 mm | 1,050 | 2,400 | 950 | — | — | 230 | Details |
![]() |
LWA-950-02AC | 43 mm | 1,050 | 2,600 | 950 | — | — | 120 | Details |
![]() |
LWA-950-03AC | 43 mm | 1,050 | 2,400 | 950 | — | — | 230 | Details |
![]() |
LWA-950-04AC | 43 mm | 1,050 | 2,600 | 950 | — | 2,850 | 220-240 | Details |
![]() |
LWB-180B-01AC | 24 mm | 600 | 800 | 180 | — | — | 230 | Details |
![]() |
LWB-180B-02AC | 24 mm | 600 | 800 | 180 | — | — | 120 | Details |
![]() |
LWB-180B-03AC | 24 mm | 600 | 800 | 180 | — | — | 220 | Details |
![]() |
LWB-250E-01AC | 31 mm | 700 | 900 | 250 | — | — | 230 | Details |
![]() |
LWB-250E-02AC | 31 mm | 700 | 1,400 | 250 | — | — | 120 | Details |
![]() |
LWB-250E-03AC | 31 mm | 700 | 1,000 | 250 | — | — | 220 | Details |
![]() |
LWB-280B-01AC | 24 mm | 800 | 1,000 | 280 | — | — | 230 | Details |
![]() |
LWB-280B-02AC | 24 mm | 800 | 1,000 | 280 | — | — | 120 | Details |
![]() |
LWB-280B-03AC | 24 mm | 800 | 1,000 | 280 | — | — | 220 | Details |
![]() |
LWT-1125-01AC | 49 mm | 4,100 | 1,700 | 1,125 | — | — | 230 | Details |
![]() |
LWT-1125-02AC | 49 mm | 4,100 | 1,700 | 1,125 | — | — | 120 | Details |
![]() |
LWT-1500-01AC | 49 mm | 4,300 | 1,900 | 1,500 | — | — | 230 | Details |
![]() |
LWT-1500-02AC | 49 mm | 4,300 | 1,900 | 1,500 | — | — | 120 | Details |
![]() |
LWT-2250-01AC | 49 mm | 4,800 | 2,200 | 2,250 | — | — | 230 | Details |
![]() |
LWT-2250-02AC | 49 mm | 4,800 | 2,200 | 2,250 | — | — | 120 | Details |
Air Blowers (Air Knife / Air Pump) — selection guide
Air Blowers (Air Knife / Air Pump): 40 models, frame sizes 24–49 mm, maximum airflow 600–4,800 m³/h, static pressure to 2,650 Pa, AC motors, across 0 series.
AC air blowers for blow-off, drying and air-knife duties: LWB compact blowers (Ø24–37 mm impeller, 600–850 m³/h at 800–1,900 Pa, 180–550 W) and LWT blowers (Ø43–49 mm, 850–4,800 m³/h at 1,700–2,650 Pa, 680–2,250 W) on 230 V, 120 V and 220–240 V. These are high-speed units that deliver a concentrated air stream rather than volume ventilation.
How to select from this range
- Select by the pressure at the nozzle or air knife, then check airflow; the two are traded across the curve.
- Specify 120 V for North American equipment, 230 V for Europe; both are listed.
- Plan for the sound level — high-pressure blowers are loud; remote mounting and a silencer are usual.
Where these fans are used
- Air knives and blow-off drying
- Inflatables and air mattresses
- Dust removal on production lines
- Combustion air for burners
Curves marked “measured” come from our own test rigs per AMCA 210 / ISO 5801 methods; digitised catalogue curves are flagged as such in the selector — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — Air Blowers (Air Knife / Air Pump)
What is the difference between the LWB and LWT blowers?
LWB are the compact 180–550 W units to 1,900 Pa; LWT are the 680–2,250 W units to 2,650 Pa and 4,800 m³/h for air knives and larger drying duties.