Axial Fans

Filter by duty point435 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAA2D200S-7MKW-10 LWAA2D200S-7MKW-10AC Ø200 mm 1,009 see curve 70 60 2,400 380/400 Details
LWAA2D200S-7MNW-01 LWAA2D200S-7MNW-01AC Ø200 mm 906 see curve 65 53 2,300 380 Details
LWAA2D200S-7MNW-02 LWAA2D200S-7MNW-02AC Ø200 mm 1,009 see curve 80 55 2,600 380 Details
LWAA2D230S-5MNW-01 LWAA2D230S-5MNW-01AC Ø230 mm 1,288 see curve 90 59 2,700 380 Details
LWAA2D230S-5MNW-02 LWAA2D230S-5MNW-02AC Ø230 mm 1,391 see curve 120 61 2,950 380 Details
LWAA2D250S-5MEB-03 LWAA2D250S-5MEB-03AC Ø250 mm 1,648 see curve 100 65 2,500 380 Details
LWAA2D250S-5MEB-04 LWAA2D250S-5MEB-04AC Ø250 mm 1,648 see curve 100 65 2,500 380 Details
LWAA2D250S-5MKW-11 LWAA2D250S-5MKW-11AC Ø250 mm 1,648 see curve 100 66 2,500 380 Details
LWAA2D250S-5MKW-12 LWAA2D250S-5MKW-12AC Ø250 mm 1,854 see curve 130 67 2,600 380 Details
LWAA2D300S-5MBW-05 LWAA2D300S-5MBW-05AC Ø300 mm 3,090 see curve 270 72 2,750 380 Details
LWAA2D300S-5MBW-06 LWAA2D300S-5MBW-06AC Ø300 mm 3,296 see curve 400 73 3,100 380 Details
LWAA2D300S-5MEW-05 LWAA2D300S-5MEW-05AC Ø300 mm 3,090 see curve 270 72 2,750 380/400 Details
LWAA2D300S-5MEW-06 LWAA2D300S-5MEW-06AC Ø300 mm 3,296 see curve 400 73 3,100 380/400 Details
LWAA2E185S-7MNW-01 LWAA2E185S-7MNW-01AC Ø185 mm 670 see curve 55 51 2,400 220/230 Details
LWAA2E185S-7MNW-02 LWAA2E185S-7MNW-02AC Ø185 mm 742 see curve 75 52 2,700 220/230 Details
LWAA2E200S-7MEB-03 LWAA2E200S-7MEB-03AC Ø200 mm 906 see curve 65 53 2,300 380/400 Details
LWAA2E200S-7MEB-04 LWAA2E200S-7MEB-04AC Ø200 mm 1,009 see curve 80 55 2,600 230 Details
LWAA2E200S-7MKW-07 LWAA2E200S-7MKW-07AC Ø200 mm 906 see curve 60 58 2,250 230 Details
LWAA2E200S-7MKW-08 LWAA2E200S-7MKW-08AC Ø200 mm 1,009 see curve 75 60 2,800 230 Details
LWAA2E250S-5MEB-01 LWAA2E250S-5MEB-01AC Ø250 mm 1,648 84 110 65 2,500 220/230 Details
LWAA2E250S-5MEB-02 LWAA2E250S-5MEB-02AC Ø250 mm 1,545 see curve 130 65 2,600 220/230 Details
LWAA2E250S-5MEW-22 LWAA2E250S-5MEW-22AC Ø250 mm 1,627 see curve 100 2,550 220 Details
LWAA2E250S-5MKW-09 LWAA2E250S-5MKW-09AC Ø250 mm 1,648 see curve 90 66 2,600 220/230 Details
LWAA2E250S-5MKW-10 LWAA2E250S-5MKW-10AC Ø250 mm 1,854 see curve 115 67 2,900 220/230 Details
LWAA2E250S-7MEB-15 LWAA2E250S-7MEB-15AC Ø250 mm 2,060 see curve 130 67 2,700 220/230 Details
LWAA2E250S-7MEB-16 LWAA2E250S-7MEB-16AC Ø250 mm 2,318 see curve 170 69 2,900 220/230 Details
LWAA2E250S-7MEW-15 LWAA2E250S-7MEW-15AC Ø250 mm 2,060 see curve 130 67 2,700 230 Details
LWAA2E250S-7MEW-16 LWAA2E250S-7MEW-16AC Ø250 mm 2,060 see curve 130 69 2,700 230 Details
LWAA2E300S-5MBW-07 LWAA2E300S-5MBW-07AC Ø300 mm 3,090 see curve 270 72 2,750 230 Details
LWAA2E300S-5MBW-08 LWAA2E300S-5MBW-08AC Ø300 mm 3,502 see curve 400 73 3,000 230 Details
LWAA2E300S-5MEW-07 LWAA2E300S-5MEW-07AC Ø300 mm 3,090 391 270 72 2,750 220 Details
LWAA2E300S-5MEW-08 LWAA2E300S-5MEW-08AC Ø300 mm 3,502 see curve 400 73 3,000 220 Details
LWAA2E300S-5MEW-14 LWAA2E300S-5MEW-14AC Ø300 mm 2,575 see curve 180 60 2,300 220 Details
LWAA4D250S-7MEB-07 LWAA4D250S-7MEB-07AC Ø250 mm 979 see curve 100 53 1,400 380 Details
LWAA4D250S-7MEB-08 LWAA4D250S-7MEB-08AC Ø250 mm 1,133 see curve 100 54 1,650 380 Details
LWAA4D295S-5PNW-03 LWAA4D295S-5PNW-03AC Ø295 mm 1,803 see curve 75 49 1,330 380 Details
LWAA4D295S-5PNW-04 LWAA4D295S-5PNW-04AC Ø295 mm 2,009 see curve 90 50 1,450 380 Details
LWAA4D300S-5MEB-03 LWAA4D300S-5MEB-03AC Ø300 mm 1,803 see curve 90 52 1,380 380 Details
LWAA4D300S-5MEB-04 LWAA4D300S-5MEB-04AC Ø300 mm 2,060 see curve 120 55 1,640 380 Details
LWAA4D350S-5MEB-03 LWAA4D350S-5MEB-03AC Ø350 mm 2,781 see curve 135 58 1,360 380 Details
Certifications for this product line
RoHS
View certificates →

Axial Fans — selection guide

Axial Fans: 435 models, impellers Ø145–1,000 mm, maximum airflow 23–48,326 m³/h, static pressure to 3,690 Pa, AC, EC and DC motors, across 98 series. 96 of them carry a measured P-Q curve and 395 a dimensional drawing.

The axial range covers Ø145 to Ø1,000 mm in five lines that overlap in diameter but not in job. LWAA AC external-rotor fans (2-, 4-, 6- and 8-pole) are the fixed-speed workhorses for condensers and heat pumps; LWAE3G EC fans add speed control and part-load efficiency on the same mounting dimensions; LWAD3G DC fans serve 24 / 48 V and 310 V DC-bus equipment; LWWAF and LWEA industrial fans move very large volumes at low pressure in wall rings and casings; and LWMFAF / LWEAF tube axial fans handle higher pressures inside a duct.

Most models are IP54 with cold-rolled-steel or PA66 impellers, rated for −30 to +60 °C ambient (EC: −25 to +60 °C), on maintenance-free ball bearings. Three-phase 380 V and single-phase 220 / 230 V versions exist for nearly every size, and the largest EC fans (Ø500–900 mm) are three-phase.

How to select from this range

  1. Use the airflow at the coil or grille and the resistance it creates — a condenser coil and guard grille cost 30–80 Pa, which is a large share of an axial fan's pressure capability.
  2. Choose diameter for airflow and speed grade (pole count or EC speed setting) for pressure and noise; two adjacent diameters usually cover the same duty with 3–6 dB(A) difference.
  3. Stay on the falling, right-hand part of the curve. Left of the pressure peak an axial fan stalls and the noise rises sharply.
  4. For condenser pressure control, night set-back or redundancy choose EC (LWAE3G); for constant duty at lowest cost choose AC (LWAA).
  5. Match the mounting format — wall ring, guard grille, short case or long case — to the drawing before ordering; the same impeller is offered in several formats.

Where these fans are used

  • Condensers, evaporators and dry coolers
  • Heat-pump and chiller outdoor units
  • Cooling towers and transformer cooling
  • Factory and warehouse ventilation
  • Tunnel and agricultural ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Axial Fans

What static pressure can LONGWELL axial fans handle?

The LWAA / LWAE3G external-rotor fans are selected up to about 100–400 Pa depending on diameter and speed; the tube axial LWMFAF / LWEAF line reaches 750–3,690 Pa total pressure at the cost of noise. Above the external-rotor range the selector will usually offer a mixed flow or centrifugal alternative.

How do I read the LWAA model code?

LWAA4E400S-5MEW: 4 = poles, E = single-phase (D = three-phase), 400 = impeller diameter in mm, then the mounting and impeller code. So a 4-pole single-phase Ø400 mm fan. LWAE3G is the EC platform, LWAD3G the DC platform on the same numbering.

Which axial sizes are offered in EC?

LWAE3G runs from Ø200 to Ø900 mm: Ø200–450 mm on 220 / 230 V single-phase, Ø500–900 mm on 380 / 400 V three-phase, all with 0–10 V / PWM control and feedback, IP54 or IP55.

Do you have 60 Hz or 115 V axial fans?

The AC line is built for 50 Hz 230 / 380 V as standard and many sizes are available for 60 Hz; the industrial LWEA line is offered in 110–120 V. EC fans accept 50 / 60 Hz on the same model. Filter the category by voltage or ask for the variant you need.