Axial Fans

Filter by duty point435 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAE3G710SS-5MKW-02 LWAE3G710SS-5MKW-02EC Ø710 mm 13,390 211 650 75 960 380 Details
LWAE3G710TS-5MKW-01 LWAE3G710TS-5MKW-01EC Ø710 mm 13,905 see curve 520 75 960 230 Details
LWAE3G710TS-5MKW-02 LWAE3G710TS-5MKW-02EC Ø710 mm 13,390 258 650 75 980 3-380 Details
LWAE3G710TS-5PKW-03 LWAE3G710TS-5PKW-03EC Ø710 mm 19,177 244 1,146 81 1,200 380/400 Details
LWAE3G800TS-3MKW-02 LWAE3G800TS-3MKW-02EC Ø800 mm 26,590 210 1,270 973 380 Details
LWAE3G800TS-3PKW-02 LWAE3G800TS-3PKW-02EC Ø800 mm 26,587 see curve 1,803 960 3-380 Details
LWAE3G800TS-4PKW-04 LWAE3G800TS-4PKW-04EC Ø800 mm 29,400 306 1,799 72 1,020 380 Details
LWAE3G800TS-5MKW-01 LWAE3G800TS-5MKW-01EC Ø800 mm 25,711 422 1,850 82 1,100 3-380 Details
LWAE3G800TS-5MKW-04 LWAE3G800TS-5MKW-04EC Ø800 mm 27,975 223 2,396 1,075 380 Details
LWAE3G800TS-5PKW-03 LWAE3G800TS-5PKW-03EC Ø800 mm 24,892 420 1,589 78 1,000 380/400 Details
LWAE3G900TS-5MGW-01 LWAE3G900TS-5MGW-01EC Ø900 mm 32,313 365 2,785 85 1,020 380 Details
LWAE3G900TS-5PKW-02 LWAE3G900TS-5PKW-02EC Ø900 mm 32,192 244 1,645 76 940 380/400 Details
LWEA1000TM-171E LWEA1000TM-171EAC Ø1000 mm 48,326 321 4,000 960 380 Details
LWEA280S(T)M-155E LWEA280S(T)M-155EAC Ø280 mm 1,605 60 180 1,450 220 Details
LWEA280S(T)M-156E LWEA280S(T)M-156EAC Ø280 mm 3,202 232 250 2,900 220 Details
LWEA300S(T)M-067E LWEA300S(T)M-067EAC Ø300 mm 2,280 see curve 180 1,450 220 Details
LWEA315S(T)M-157E LWEA315S(T)M-157EAC Ø315 mm 2,273 74 250 1,450 220 Details
LWEA315S(T)M-158E LWEA315S(T)M-158EAC Ø315 mm 4,545 373 370 2,900 220 Details
LWEA355S(T)M-159E LWEA355S(T)M-159EAC Ø355 mm 3,265 93 370 1,450 220 Details
LWEA355S(T)M-160E LWEA355S(T)M-160EAC Ø355 mm 6,542 373 750 2,900 220 Details
LWEA400S(T)M-068E LWEA400S(T)M-068EAC Ø400 mm 2,280 see curve 370 1,450 220 Details
LWEA400S(T)M-161E LWEA400S(T)M-161EAC Ø400 mm 4,687 119 550 1,450 220 Details
LWEA400S(T)M-162E LWEA400S(T)M-162EAC Ø400 mm 9,336 474 1,100 2,900 220 Details
LWEA450S(T)M-163E LWEA450S(T)M-163EAC Ø450 mm 6,658 150 550 1,450 220 Details
LWEA500S(T)M-069E LWEA500S(T)M-069EAC Ø500 mm 5,700 see curve 550 1,450 220 Details
LWEA500TM-164E LWEA500TM-164EAC Ø500 mm 9,133 185 750 1,450 380 Details
LWEA560TM-165E LWEA560TM-165EAC Ø560 mm 12,812 232 1,100 1,450 380 Details
LWEA560TM-166E LWEA560TM-166EAC Ø560 mm 8,471 110 1,100 960 380 Details
LWEA600S(T)M-070E LWEA600S(T)M-070EAC Ø600 mm 8,700 see curve 750 1,450 220 Details
LWEA630TM-167E LWEA630TM-167EAC Ø630 mm 18,250 294 1,500 1,450 380 Details
LWEA700S(T)M-071E LWEA700S(T)M-071EAC Ø700 mm 10,200 see curve 1,100 1,450 220 Details
LWEA710TM-168E LWEA710TM-168EAC Ø710 mm 26,120 373 3,000 1,450 380 Details
LWEA750S(T)M-072E LWEA750S(T)M-072EAC Ø750 mm 10,500 see curve 1,500 1,450 220 Details
LWEA800TM-169E LWEA800TM-169EAC Ø800 mm 37,370 474 4,000 1,450 380 Details
LWEA800TM-170E LWEA800TM-170EAC Ø800 mm 24,739 208 2,200 960 380 Details
LWEAF300-01 LWEAF300-01AC Ø300 mm 2,280 see curve 180 1,450 220 Details
LWEAF400-01 LWEAF400-01AC Ø400 mm 2,280 see curve 370 1,450 220 Details
LWEAF500-01 LWEAF500-01AC Ø500 mm 5,700 see curve 550 1,450 220 Details
LWEAF600-01 LWEAF600-01AC Ø600 mm 8,700 see curve 750 1,450 220 Details
LWEAF700-01 LWEAF700-01AC Ø700 mm 10,200 see curve 1,100 1,450 380 Details
Certifications for this product line
RoHS
View certificates →

Axial Fans — selection guide

Axial Fans: 435 models, impellers Ø145–1,000 mm, maximum airflow 23–48,326 m³/h, static pressure to 3,690 Pa, AC, EC and DC motors, across 98 series. 96 of them carry a measured P-Q curve and 395 a dimensional drawing.

The axial range covers Ø145 to Ø1,000 mm in five lines that overlap in diameter but not in job. LWAA AC external-rotor fans (2-, 4-, 6- and 8-pole) are the fixed-speed workhorses for condensers and heat pumps; LWAE3G EC fans add speed control and part-load efficiency on the same mounting dimensions; LWAD3G DC fans serve 24 / 48 V and 310 V DC-bus equipment; LWWAF and LWEA industrial fans move very large volumes at low pressure in wall rings and casings; and LWMFAF / LWEAF tube axial fans handle higher pressures inside a duct.

Most models are IP54 with cold-rolled-steel or PA66 impellers, rated for −30 to +60 °C ambient (EC: −25 to +60 °C), on maintenance-free ball bearings. Three-phase 380 V and single-phase 220 / 230 V versions exist for nearly every size, and the largest EC fans (Ø500–900 mm) are three-phase.

How to select from this range

  1. Use the airflow at the coil or grille and the resistance it creates — a condenser coil and guard grille cost 30–80 Pa, which is a large share of an axial fan's pressure capability.
  2. Choose diameter for airflow and speed grade (pole count or EC speed setting) for pressure and noise; two adjacent diameters usually cover the same duty with 3–6 dB(A) difference.
  3. Stay on the falling, right-hand part of the curve. Left of the pressure peak an axial fan stalls and the noise rises sharply.
  4. For condenser pressure control, night set-back or redundancy choose EC (LWAE3G); for constant duty at lowest cost choose AC (LWAA).
  5. Match the mounting format — wall ring, guard grille, short case or long case — to the drawing before ordering; the same impeller is offered in several formats.

Where these fans are used

  • Condensers, evaporators and dry coolers
  • Heat-pump and chiller outdoor units
  • Cooling towers and transformer cooling
  • Factory and warehouse ventilation
  • Tunnel and agricultural ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Axial Fans

What static pressure can LONGWELL axial fans handle?

The LWAA / LWAE3G external-rotor fans are selected up to about 100–400 Pa depending on diameter and speed; the tube axial LWMFAF / LWEAF line reaches 750–3,690 Pa total pressure at the cost of noise. Above the external-rotor range the selector will usually offer a mixed flow or centrifugal alternative.

How do I read the LWAA model code?

LWAA4E400S-5MEW: 4 = poles, E = single-phase (D = three-phase), 400 = impeller diameter in mm, then the mounting and impeller code. So a 4-pole single-phase Ø400 mm fan. LWAE3G is the EC platform, LWAD3G the DC platform on the same numbering.

Which axial sizes are offered in EC?

LWAE3G runs from Ø200 to Ø900 mm: Ø200–450 mm on 220 / 230 V single-phase, Ø500–900 mm on 380 / 400 V three-phase, all with 0–10 V / PWM control and feedback, IP54 or IP55.

Do you have 60 Hz or 115 V axial fans?

The AC line is built for 50 Hz 230 / 380 V as standard and many sizes are available for 60 Hz; the industrial LWEA line is offered in 110–120 V. EC fans accept 50 / 60 Hz on the same model. Filter the category by voltage or ask for the variant you need.

Related selections

Scroll to Top
RFQ list