Axial Fans

Filter by duty point435 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAA4D350S-5MEB-04 LWAA4D350S-5MEB-04AC Ø350 mm 2,575 see curve 180 67 1,500 380 Details
LWAA4D350S-5MEB-11 LWAA4D350S-5MEB-11AC Ø350 mm 3,348 see curve 155 55 1,350 380 Details
LWAA4D350S-5MEB-12 LWAA4D350S-5MEB-12AC Ø350 mm 3,760 see curve 200 58 1,500 380 Details
LWAA4D350S-5MEW-18 LWAA4D350S-5MEW-18AC Ø350 mm 2,575 see curve 150 1,400 380 Details
LWAA4D350S-5MKB-15 LWAA4D350S-5MKB-15AC Ø350 mm 3,348 see curve 155 55 1,350 380 Details
LWAA4D350S-5MKB-16 LWAA4D350S-5MKB-16AC Ø350 mm 2,987 see curve 180 65 1,500 480 Details
LWAA4D400S-5MEB-03 LWAA4D400S-5MEB-03AC Ø400 mm 3,811 see curve 180 60 1,370 380 Details
LWAA4D400S-5MEB-04 LWAA4D400S-5MEB-04AC Ø400 mm 4,223 see curve 240 62 1,620 380 Details
LWAA4D400S-5MEB-11 LWAA4D400S-5MEB-11AC Ø400 mm 4,532 see curve 230 62 1,350 380 Details
LWAA4D400S-5MEB-12 LWAA4D400S-5MEB-12AC Ø400 mm 5,150 see curve 280 64 1,600 380 Details
LWAA4D400S-5MEB-15 LWAA4D400S-5MEB-15AC Ø400 mm 4,429 see curve 225 58 1,380 380/400 Details
LWAA4D400S-5MEB-16 LWAA4D400S-5MEB-16AC Ø400 mm 4,893 see curve 310 60 1,400 380/400 Details
LWAA4D400S-5MEW-22 LWAA4D400S-5MEW-22AC Ø400 mm 4,069 see curve 180 66 1,400 380 Details
LWAA4D400S-5MKB-19 LWAA4D400S-5MKB-19AC Ø400 mm 4,429 see curve 225 58 1,380 380 Details
LWAA4D400S-5MKB-20 LWAA4D400S-5MKB-20AC Ø400 mm 4,069 see curve 180 60 1,400 380 Details
LWAA4D420S-5MEB-03 LWAA4D420S-5MEB-03AC Ø420 mm 5,459 see curve 280 65 1,370 380 Details
LWAA4D420S-5MEB-04 LWAA4D420S-5MEB-04AC Ø420 mm 5,974 see curve 380 68 1,600 380 Details
LWAA4D450S-5MEB-03 LWAA4D450S-5MEB-03AC Ø450 mm 4,635 see curve 250 62 1,350 380 Details
LWAA4D450S-5MEB-04 LWAA4D450S-5MEB-04AC Ø450 mm 4,944 see curve 280 64 1,600 380 Details
LWAA4D450S-5MEB-10 LWAA4D450S-5MEB-10AC Ø450 mm 7,004 see curve 480 66 1,350 380 Details
LWAA4D450S-5MEB-12 LWAA4D450S-5MEB-12AC Ø450 mm 5,768 see curve 380 64 1,350 380 Details
LWAA4D450S-5MEB-16 LWAA4D450S-5MEB-16AC Ø450 mm 5,150 see curve 270 58 1,350 380 Details
LWAA4D450S-5MEB-17 LWAA4D450S-5MEB-17AC Ø450 mm 7,725 see curve 730 72 1,540 380 Details
LWAA4D450S-5MEW-23 LWAA4D450S-5MEW-23AC Ø450 mm 5,562 see curve 280 1,390 380 Details
LWAA4D450S-5MKB-20 LWAA4D450S-5MKB-20AC Ø450 mm 5,459 see curve 270 58 1,350 380 Details
LWAA4D450S-5MKB-21 LWAA4D450S-5MKB-21AC Ø450 mm 5,665 see curve 330 60 1,400 380 Details
LWAA4D500S-5MEB-03 LWAA4D500S-5MEB-03AC Ø500 mm 6,695 see curve 420 69 1,350 380 Details
LWAA4D500S-5MEB-04 LWAA4D500S-5MEB-04AC Ø500 mm 7,004 see curve 500 70 1,500 380 Details
LWAA4D500S-5MEB-10 LWAA4D500S-5MEB-10AC Ø500 mm 9,270 see curve 750 80 1,350 380 Details
LWAA4D500S-5MEW-12 LWAA4D500S-5MEW-12AC Ø500 mm 7,519 see curve 450 69 1,390 380 Details
LWAA4D500S-5MEW-13 LWAA4D500S-5MEW-13AC Ø500 mm 7,931 see curve 450 70 1,390 380 Details
LWAA4D500S-7MGB-11 LWAA4D500S-7MGB-11AC Ø500 mm 9,270 see curve 800 80 1,350 380 Details
LWAA4D500S-7MKB-11 LWAA4D500S-7MKB-11AC Ø500 mm 9,270 see curve 800 80 1,350 380/400 Details
LWAA4D550S-5MEB-03 LWAA4D550S-5MEB-03AC Ø550 mm 8,034 see curve 550 73 1,330 380 Details
LWAA4D550S-5MEB-04 LWAA4D550S-5MEB-04AC Ø550 mm 8,755 see curve 725 74 1,540 380 Details
LWAA4D550S-5MEW-09 LWAA4D550S-5MEW-09AC Ø550 mm 9,116 see curve 650 1,350 380 Details
LWAA4D550S-5MKB-10 LWAA4D550S-5MKB-10AC Ø550 mm 8,034 194 550 73 1,330 380 Details
LWAA4D600B-5MEW-10 LWAA4D600B-5MEW-10AC Ø600 mm 11,794 185 950 1,350 380 Details
LWAA4D600S-5MEB-01 LWAA4D600S-5MEB-01AC Ø600 mm 10,506 see curve 800 69 1,350 380 Details
LWAA4D630S-5MEB-01 LWAA4D630S-5MEB-01AC Ø630 mm 11,948 see curve 850 75 1,350 380 Details
Certifications for this product line
RoHS
View certificates →

Axial Fans — selection guide

Axial Fans: 435 models, impellers Ø145–1,000 mm, maximum airflow 23–48,326 m³/h, static pressure to 3,690 Pa, AC, EC and DC motors, across 98 series. 96 of them carry a measured P-Q curve and 395 a dimensional drawing.

The axial range covers Ø145 to Ø1,000 mm in five lines that overlap in diameter but not in job. LWAA AC external-rotor fans (2-, 4-, 6- and 8-pole) are the fixed-speed workhorses for condensers and heat pumps; LWAE3G EC fans add speed control and part-load efficiency on the same mounting dimensions; LWAD3G DC fans serve 24 / 48 V and 310 V DC-bus equipment; LWWAF and LWEA industrial fans move very large volumes at low pressure in wall rings and casings; and LWMFAF / LWEAF tube axial fans handle higher pressures inside a duct.

Most models are IP54 with cold-rolled-steel or PA66 impellers, rated for −30 to +60 °C ambient (EC: −25 to +60 °C), on maintenance-free ball bearings. Three-phase 380 V and single-phase 220 / 230 V versions exist for nearly every size, and the largest EC fans (Ø500–900 mm) are three-phase.

How to select from this range

  1. Use the airflow at the coil or grille and the resistance it creates — a condenser coil and guard grille cost 30–80 Pa, which is a large share of an axial fan's pressure capability.
  2. Choose diameter for airflow and speed grade (pole count or EC speed setting) for pressure and noise; two adjacent diameters usually cover the same duty with 3–6 dB(A) difference.
  3. Stay on the falling, right-hand part of the curve. Left of the pressure peak an axial fan stalls and the noise rises sharply.
  4. For condenser pressure control, night set-back or redundancy choose EC (LWAE3G); for constant duty at lowest cost choose AC (LWAA).
  5. Match the mounting format — wall ring, guard grille, short case or long case — to the drawing before ordering; the same impeller is offered in several formats.

Where these fans are used

  • Condensers, evaporators and dry coolers
  • Heat-pump and chiller outdoor units
  • Cooling towers and transformer cooling
  • Factory and warehouse ventilation
  • Tunnel and agricultural ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Axial Fans

What static pressure can LONGWELL axial fans handle?

The LWAA / LWAE3G external-rotor fans are selected up to about 100–400 Pa depending on diameter and speed; the tube axial LWMFAF / LWEAF line reaches 750–3,690 Pa total pressure at the cost of noise. Above the external-rotor range the selector will usually offer a mixed flow or centrifugal alternative.

How do I read the LWAA model code?

LWAA4E400S-5MEW: 4 = poles, E = single-phase (D = three-phase), 400 = impeller diameter in mm, then the mounting and impeller code. So a 4-pole single-phase Ø400 mm fan. LWAE3G is the EC platform, LWAD3G the DC platform on the same numbering.

Which axial sizes are offered in EC?

LWAE3G runs from Ø200 to Ø900 mm: Ø200–450 mm on 220 / 230 V single-phase, Ø500–900 mm on 380 / 400 V three-phase, all with 0–10 V / PWM control and feedback, IP54 or IP55.

Do you have 60 Hz or 115 V axial fans?

The AC line is built for 50 Hz 230 / 380 V as standard and many sizes are available for 60 Hz; the industrial LWEA line is offered in 110–120 V. EC fans accept 50 / 60 Hz on the same model. Filter the category by voltage or ask for the variant you need.

Related selections

Scroll to Top
RFQ list