ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAE3G400ST-5MEW-08 LWAE3G400ST-5MEW-08EC Ø400 mm 5,562 258 360 67 1,600 220/230 Details
LWAE3G400ST-5MGW-06 LWAE3G400ST-5MGW-06EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G400ST-5MNW-02 LWAE3G400ST-5MNW-02EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G450SS-5MEW-03 LWAE3G450SS-5MEW-03EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450SS-5MEW-07 LWAE3G450SS-5MEW-07EC Ø450 mm 6,386 232 445 68 1,600 220/230 Details
LWAE3G450SS-5MEW-09 LWAE3G450SS-5MEW-09EC Ø450 mm 5,871 163 264 67 1,670 230 Details
LWAE3G450SS-5MGW-05 LWAE3G450SS-5MGW-05EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450SS-5MNW-01 LWAE3G450SS-5MNW-01EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450SS-5PEW-10 LWAE3G450SS-5PEW-10EC Ø450 mm 4,266 80 100 52 1,080 220 Details
LWAE3G450ST-5MEW-04 LWAE3G450ST-5MEW-04EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450ST-5MEW-08 LWAE3G450ST-5MEW-08EC Ø450 mm 6,386 232 445 68 1,600 220/230 Details
LWAE3G450ST-5MGW-06 LWAE3G450ST-5MGW-06EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450ST-5MNW-02 LWAE3G450ST-5MNW-02EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G500SS-5MEW-11 LWAE3G500SS-5MEW-11EC Ø500 mm 6,971 176 343 67 1,380 230 Details
LWAE3G500SS-5PKW-12 LWAE3G500SS-5PKW-12EC Ø500 mm 9,122 143 586 78 1,400 230 Details
LWAE3G500SS-5PKW-15 LWAE3G500SS-5PKW-15EC Ø500 mm 5,900 see curve 200 56 900 230 Details
LWAE3G500TS-5MEW-03 LWAE3G500TS-5MEW-03EC Ø500 mm 10,506 330 850 78 1,690 380 Details
LWAE3G500TS-5MKW-05 LWAE3G500TS-5MKW-05EC Ø500 mm 10,506 330 850 78 1,690 380 Details
LWAE3G500TS-5MNW-01 LWAE3G500TS-5MNW-01EC Ø500 mm 10,506 330 850 78 1,690 380 Details
LWAE3G500TT-5MEW-04 LWAE3G500TT-5MEW-04EC Ø500 mm 10,506 330 850 78 1,690 380 Details
LWAE3G500TT-5MKW-06 LWAE3G500TT-5MKW-06EC Ø500 mm 10,506 330 850 78 1,690 380 Details
LWAE3G500TT-5MNW-02 LWAE3G500TT-5MNW-02EC Ø500 mm 10,506 330 850 78 1,690 380 Details
LWAE3G550TS-5MEW-03 LWAE3G550TS-5MEW-03EC Ø550 mm 12,154 278 950 78 1,690 380 Details
LWAE3G550TS-5MKW-05 LWAE3G550TS-5MKW-05EC Ø550 mm 12,154 280 950 78 1,690 380 Details
LWAE3G550TS-5MNW-01 LWAE3G550TS-5MNW-01EC Ø550 mm 12,154 330 850 78 1,690 380 Details
LWAE3G550TT-5MEW-04 LWAE3G550TT-5MEW-04EC Ø550 mm 12,154 330 850 78 1,690 380 Details
LWAE3G550TT-5MKW-06 LWAE3G550TT-5MKW-06EC Ø550 mm 12,154 278 850 78 1,690 380 Details
LWAE3G550TT-5MNW-02 LWAE3G550TT-5MNW-02EC Ø550 mm 10,506 330 850 78 1,690 380 Details
LWAE3G630SS-5MKW-07 LWAE3G630SS-5MKW-07EC Ø630 mm 12,875 216 588 75 930 230 Details
LWAE3G630SS-5PKW-10 LWAE3G630SS-5PKW-10EC Ø630 mm 12,777 188 679 70 1,086 230 Details
LWAE3G630TS-5MEW-03 LWAE3G630TS-5MEW-03EC Ø630 mm 14,935 238 800 69 1,150 380 Details
LWAE3G630TS-5MKW-05 LWAE3G630TS-5MKW-05EC Ø630 mm 14,935 238 800 69 1,150 380 Details
LWAE3G630TS-5MKW-08 LWAE3G630TS-5MKW-08EC Ø630 mm 13,905 256 780 74 1,020 3 Details
LWAE3G630TS-5MKW-09 LWAE3G630TS-5MKW-09EC Ø630 mm 12,566 258 580 75 930 3 Details
LWAE3G630TS-5MNW-01 LWAE3G630TS-5MNW-01EC Ø630 mm 14,935 238 800 69 1,150 380 Details
LWAE3G630TS-5PEW-11 LWAE3G630TS-5PEW-11EC Ø630 mm 13,670 224 887 74 1,200 380/400 Details
LWAE3G630TT-5MEW-04 LWAE3G630TT-5MEW-04EC Ø630 mm 14,935 238 800 69 1,150 380 Details
LWAE3G630TT-5MKW-06 LWAE3G630TT-5MKW-06EC Ø630 mm 14,935 238 800 69 1,250 380 Details
LWAE3G630TT-5MNW-02 LWAE3G630TT-5MNW-02EC Ø630 mm 14,935 238 800 69 1,150 380 Details
LWAE3G710SS-5MEW-01 LWAE3G710SS-5MEW-01EC Ø710 mm 13,905 218 520 75 960 230 Details
Certifications for this product line
RoHS
View certificates →

Axial Fans — selection guide

Axial Fans: 435 models, impellers Ø145–1,000 mm, maximum airflow 23–48,326 m³/h, static pressure to 3,690 Pa, AC, EC and DC motors, across 98 series. 96 of them carry a measured P-Q curve and 395 a dimensional drawing.

The axial range covers Ø145 to Ø1,000 mm in five lines that overlap in diameter but not in job. LWAA AC external-rotor fans (2-, 4-, 6- and 8-pole) are the fixed-speed workhorses for condensers and heat pumps; LWAE3G EC fans add speed control and part-load efficiency on the same mounting dimensions; LWAD3G DC fans serve 24 / 48 V and 310 V DC-bus equipment; LWWAF and LWEA industrial fans move very large volumes at low pressure in wall rings and casings; and LWMFAF / LWEAF tube axial fans handle higher pressures inside a duct.

Most models are IP54 with cold-rolled-steel or PA66 impellers, rated for −30 to +60 °C ambient (EC: −25 to +60 °C), on maintenance-free ball bearings. Three-phase 380 V and single-phase 220 / 230 V versions exist for nearly every size, and the largest EC fans (Ø500–900 mm) are three-phase.

How to select from this range

  1. Use the airflow at the coil or grille and the resistance it creates — a condenser coil and guard grille cost 30–80 Pa, which is a large share of an axial fan's pressure capability.
  2. Choose diameter for airflow and speed grade (pole count or EC speed setting) for pressure and noise; two adjacent diameters usually cover the same duty with 3–6 dB(A) difference.
  3. Stay on the falling, right-hand part of the curve. Left of the pressure peak an axial fan stalls and the noise rises sharply.
  4. For condenser pressure control, night set-back or redundancy choose EC (LWAE3G); for constant duty at lowest cost choose AC (LWAA).
  5. Match the mounting format — wall ring, guard grille, short case or long case — to the drawing before ordering; the same impeller is offered in several formats.

Where these fans are used

  • Condensers, evaporators and dry coolers
  • Heat-pump and chiller outdoor units
  • Cooling towers and transformer cooling
  • Factory and warehouse ventilation
  • Tunnel and agricultural ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Axial Fans

What static pressure can LONGWELL axial fans handle?

The LWAA / LWAE3G external-rotor fans are selected up to about 100–400 Pa depending on diameter and speed; the tube axial LWMFAF / LWEAF line reaches 750–3,690 Pa total pressure at the cost of noise. Above the external-rotor range the selector will usually offer a mixed flow or centrifugal alternative.

How do I read the LWAA model code?

LWAA4E400S-5MEW: 4 = poles, E = single-phase (D = three-phase), 400 = impeller diameter in mm, then the mounting and impeller code. So a 4-pole single-phase Ø400 mm fan. LWAE3G is the EC platform, LWAD3G the DC platform on the same numbering.

Which axial sizes are offered in EC?

LWAE3G runs from Ø200 to Ø900 mm: Ø200–450 mm on 220 / 230 V single-phase, Ø500–900 mm on 380 / 400 V three-phase, all with 0–10 V / PWM control and feedback, IP54 or IP55.

Do you have 60 Hz or 115 V axial fans?

The AC line is built for 50 Hz 230 / 380 V as standard and many sizes are available for 60 Hz; the industrial LWEA line is offered in 110–120 V. EC fans accept 50 / 60 Hz on the same model. Filter the category by voltage or ask for the variant you need.