Tube Axial Fans

Tube-cased axial fans for in-duct installation, combining airflow with a compact mounting length. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Browse by series

Filter by duty point36 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

Certifications for this product line
RoHS
View certificates →

Tube Axial Fans — selection guide

Tube Axial Fans: 36 models, impellers Ø200–750 mm, maximum airflow 23–15,000 m³/h, static pressure to 3,690 Pa, AC motors, across 18 series.

Tube axial fans (LWMFAF, LWEAF and LWEA S(T)M) are axial or mixed-flow impellers in a cylindrical casing for in-duct installation, Ø200 to Ø750 mm. The LWMFAF mixed-flow tube fans develop 750–3,690 Pa total pressure — far more than an open axial fan — at the cost of sound levels of 87–95 dB(A), so they are used where pressure and compactness matter more than noise: process exhaust, drying, tunnels and booster duty.

How to select from this range

  1. Select on total pressure at the flange; the casing recovers velocity pressure that an open fan loses.
  2. Plan silencers or remote mounting from the outset — these fans are loud.
  3. Match the casing length and flange to the duct standard on the drawing.

Where these fans are used

  • Process and kiln exhaust
  • Drying and paint-line ventilation
  • Tunnel and mine ventilation
  • Duct boosters

Curves marked “measured” come from our own test rigs per AMCA 210 / ISO 5801 methods; digitised catalogue curves are flagged as such in the selector — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Tube Axial Fans

Why is the pressure of a tube axial fan so much higher than an open axial fan?

The LWMFAF units use a mixed-flow impeller and a diffuser casing, which adds a centrifugal pressure component and recovers velocity pressure; the LWEAF / LWEA S(T)M units are conventional cased axial fans in the lower part of the range.

Which voltages are available?

110–120 V (15 models), 220 V and 380 V three-phase; check the voltage filter for the size you need.

Related selections

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top