Cross Flow Fans

Cross flow (tangential) fans deliver a long, even air curtain at low noise — the standard solution for indoor AC units, air curtains, elevator ventilation and linear air supply. Impeller length is made to the door opening or chamber size. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point318 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCA-100380SN-06 LWCA-100380SN-06AC Ø100 mm 700 95 60 55 1,400 230 Details
LWCA-100520SN-06 LWCA-100520SN-06AC Ø100 mm 950 128 75 58 1,400 230 Details
LWCA-100620SN-06 LWCA-100620SN-06AC Ø100 mm 1,100 151 90 59 1,400 230 Details
LWCA-100720SN-06 LWCA-100720SN-06AC Ø100 mm 1,300 175 100 60 1,400 230 Details
LWCA-100820SN-06 LWCA-100820SN-06AC Ø100 mm 1,500 203 110 61 1,400 230 Details
LWCA-110380SN-06 LWCA-110380SN-06AC Ø110 mm 900 128 90 61 1,250 230 Details
LWCA-110520SN-06 LWCA-110520SN-06AC Ø110 mm 1,200 162 95 63 1,250 230 Details
LWCA-110620SN-06 LWCA-110620SN-06AC Ø110 mm 1,350 193 100 66 1,250 230 Details
LWCA-110720SN-06 LWCA-110720SN-06AC Ø110 mm 1,550 224 105 67 1,250 230 Details
LWCA-110820SN-06 LWCA-110820SN-06AC Ø110 mm 1,750 255 115 68 1,250 230 Details
LWCA-120380SN-06 LWCA-120380SN-06AC Ø120 mm 1,000 68 109 63 1,350 230 Details
LWCA-120560SN-06 LWCA-120560SN-06AC Ø120 mm 1,380 100 120 65 1,350 230 Details
LWCA-120680SN-06 LWCA-120680SN-06AC Ø120 mm 1,560 122 135 67 1,350 230 Details
LWCA-120780SN-06 LWCA-120780SN-06AC Ø120 mm 1,780 140 150 71 1,350 230 Details
LWCA-120900SN-06 LWCA-120900SN-06AC Ø120 mm 2,000 161 170 72 1,350 230 Details
LWCA-1501000SN-06 LWCA-1501000SN-06AC Ø150 mm 3,000 110 195 72 800 230 Details
LWCA-1501200SN-06 LWCA-1501200SN-06AC Ø150 mm 4,000 135 210 75 800 230 Details
LWCA-150380SN-06 LWCA-150380SN-06AC Ø150 mm 1,200 52 170 69 1,000 230 Details
LWCA-150500SN-06 LWCA-150500SN-06AC Ø150 mm 1,800 70 190 70 1,000 230 Details
LWCA-150700SN-06 LWCA-150700SN-06AC Ø150 mm 2,500 85 180 71 800 230 Details
LWCA-30150SN-07 LWCA-30150SN-07AC Ø30 mm 38 9 10 25 2,400 230 Details
LWCA-30150UN-06 LWCA-30150UN-06AC Ø30 mm 38 9 9 25 2,400 115 Details
LWCA-30190SN-07 LWCA-30190SN-07AC Ø30 mm 47 10 11 26 2,400 230 Details
LWCA-30190UN-06 LWCA-30190UN-06AC Ø30 mm 47 10 9 26 2,400 115 Details
LWCA-30250SN-07 LWCA-30250SN-07AC Ø30 mm 59 11 10 26 2,400 230 Details
LWCA-30250UN-06 LWCA-30250UN-06AC Ø30 mm 59 11 11 26 2,400 115 Details
LWCA-30290SN-07 LWCA-30290SN-07AC Ø30 mm 71 12 11 27 2,400 230 Details
LWCA-30290UN-06 LWCA-30290UN-06AC Ø30 mm 71 12 12 27 2,400 115 Details
LWCA-30350SN-07 LWCA-30350SN-07AC Ø30 mm 84 13 11 27 2,400 230 Details
LWCA-30350UN-06 LWCA-30350UN-06AC Ø30 mm 84 13 13 27 2,400 115 Details
LWCA-30420SN-07 LWCA-30420SN-07AC Ø30 mm 100 14 11 28 2,400 230 Details
LWCA-30420UN-06 LWCA-30420UN-06AC Ø30 mm 100 14 13 28 2,400 115 Details
LWCA-30530SN-06 LWCA-30530SN-06AC Ø30 mm 137 13 13 29 2,200 230 Details
LWCA-30610SN-06 LWCA-30610SN-06AC Ø30 mm 158 13 13 29 2,200 230 Details
LWCA-30650SN-06 LWCA-30650SN-06AC Ø30 mm 168 14 14 29 2,200 230 Details
LWCA-30718SN-06 LWCA-30718SN-06AC Ø30 mm 185 14 15 30 2,200 230 Details
LWCA-30800SN-06 LWCA-30800SN-06AC Ø30 mm 207 15 15 31 2,200 230 Details
LWCA-30854SN-06 LWCA-30854SN-06AC Ø30 mm 221 16 15 31 2,200 230 Details
LWCA-3090SN-07 LWCA-3090SN-07AC Ø30 mm 23 8 8 25 2,400 230 Details
LWCA-3090UN-06 LWCA-3090UN-06AC Ø30 mm 23 8 8 25 2,400 115 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

Cross Flow Fans: 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure to 320 Pa, DC, AC and EC motors, across 236 series.

Cross flow (tangential) fans are specified by two numbers that both appear in the model code: impeller diameter and impeller length. LWCA-1501200 is a Ø150 mm impeller 1,200 mm long on an AC motor; LWCD is the 12 / 24 V DC line and LWCE the 230 V EC line. Diameters run from Ø30 to Ø150 mm and lengths from about 90 mm to 1,200 mm, all with aluminium-alloy impellers on maintenance-free ball bearings.

The discharge is a flat, even curtain as wide as the impeller, at low static pressure (8–320 Pa across the range). That makes the family the standard fan for indoor air-conditioner units, air curtains, elevator cabins, fireplaces and any appliance that needs a wide, quiet air stream from a slim housing.

How to select from this range

  1. Start from the housing: the impeller length must match the discharge opening, and the diameter is limited by the housing depth.
  2. Airflow scales almost linearly with length at a given diameter and speed, so a longer impeller at lower speed is the quiet way to reach a target airflow.
  3. Keep the air path open — cross flow fans develop little static pressure, so filters and grilles must be coarse.
  4. Pick the motor line by the appliance: LWCA for mains-powered units with two- or three-speed tapping, LWCD for battery or low-voltage designs with voltage / PWM control, LWCE for 230 V units that need stepless control and feedback.
  5. Confirm bearing side, shaft and lead-out position on the drawing; many combinations are made to order.

Where these fans are used

  • Indoor units of split and ducted air conditioners
  • Air curtains and door air barriers
  • Elevator cabin ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery-pack cooling

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cross Flow Fans

How do I read a cross flow fan model number?

LWCA-1501200SN-06: LWCA = AC line (LWCD = DC, LWCE = EC), 150 = impeller diameter in mm, 1200 = impeller length in mm, then the motor / mounting code and version. Compare models within the same diameter to trade length against speed.

What is the longest impeller you make?

Standard lengths in the catalogue reach 1,200 mm at Ø120–150 mm. Longer impellers are made with an intermediate bearing on request.

Can a cross flow fan work against a duct?

Only against very low resistance — typically below 100 Pa. For ducted duties choose an inline duct fan or a centrifugal blower; the selector will offer them if you enter a higher static pressure.

Which cross flow fans are ETL listed?

The DC cross flow line (LWCD, 12 / 24 / 48 V) is ETL listed under Intertek control no. 5022563 to UL 507 / CSA C22.2 No. 113. See the certificate scans on the R&D and certifications page.

Related selections

Scroll to Top
RFQ list