Cross Flow Fans

Filter by duty point318 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCA-80620SN-06 LWCA-80620SN-06AC Ø80 mm 700 63 35 54 1,350 230 Details
LWCA-80720SN-06 LWCA-80720SN-06AC Ø80 mm 780 73 38 55 1,350 230 Details
LWCA-80820SN-06 LWCA-80820SN-06AC Ø80 mm 880 82 40 56 1,350 230 Details
LWCA-90360SN-06 LWCA-90360SN-06AC Ø90 mm 550 61 33 53 1,350 230 Details
LWCA-90520SN-06 LWCA-90520SN-06AC Ø90 mm 770 77 55 54 1,350 230 Details
LWCA-90680SN-06 LWCA-90680SN-06AC Ø90 mm 1,000 97 72 55 1,350 230 Details
LWCA-90800SN-06 LWCA-90800SN-06AC Ø90 mm 1,150 120 83 58 1,350 230 Details
LWCA-90920SN-06 LWCA-90920SN-06AC Ø90 mm 1,300 140 93 59 1,350 230 Details
LWCD-100380MN-06 LWCD-100380MN-06DC Ø100 mm 800 106 26.5 55 1,500 24 Details
LWCD-100520MN-06 LWCD-100520MN-06DC Ø100 mm 1,100 145 60 58 1,500 24 Details
LWCD-100620MN-06 LWCD-100620MN-06DC Ø100 mm 1,300 173 75 59 1,500 24 Details
LWCD-100720MN-06 LWCD-100720MN-06DC Ø100 mm 1,500 197 115.2 60 1,500 24 Details
LWCD-100820MN-06 LWCD-100820MN-06DC Ø100 mm 1,700 229 120 61 1,500 24 Details
LWCD-110380MN-06 LWCD-110380MN-06DC Ø110 mm 881 141 70 55 1,200 24 Details
LWCD-110520MN-06 LWCD-110520MN-06DC Ø110 mm 1,205 202 100 57 1,200 24 Details
LWCD-110620MN-06 LWCD-110620MN-06DC Ø110 mm 1,437 244 120 57 1,200 24 Details
LWCD-110720MN-06 LWCD-110720MN-06DC Ø110 mm 1,669 278 132 58 1,200 24 Details
LWCD-110820MN-06 LWCD-110820MN-06DC Ø110 mm 1,845 320 146 59 1,200 24 Details
LWCD-120380MN-06 LWCD-120380MN-06DC Ø120 mm 900 68 48 56 1,350 24 Details
LWCD-120490MN-06 LWCD-120490MN-06DC Ø120 mm 1,160 88 90 57 1,350 24 Details
LWCD-120560MN-06 LWCD-120560MN-06DC Ø120 mm 1,350 100 110 57 1,350 24 Details
LWCD-120680MN-06 LWCD-120680MN-06DC Ø120 mm 1,600 122 123 58 1,350 24 Details
LWCD-120780MN-06 LWCD-120780MN-06DC Ø120 mm 1,900 140 144 60 1,350 24 Details
LWCD-150380MN-06 LWCD-150380MN-06DC Ø150 mm 1,350 50 80 62 100 24 Details
LWCD-150500MN-06 LWCD-150500MN-06DC Ø150 mm 1,600 63 84 60 800 24 Details
LWCD-150700MN-06 LWCD-150700MN-06DC Ø150 mm 2,500 83 105 60 800 24 Details
LWCD-301082MN-06 LWCD-301082MN-06DC Ø30 mm 279 21 5.76 38 2,400 24 Details
LWCD-30150LN-06 LWCD-30150LN-06DC Ø30 mm 43 13 1.2 27 2,400 12 Details
LWCD-30150MN-07 LWCD-30150MN-07DC Ø30 mm 43 13 1.2 27 2,400 24 Details
LWCD-30190LN-06 LWCD-30190LN-06DC Ø30 mm 55 14 55 29 2,400 12 Details
LWCD-30190MN-07 LWCD-30190MN-07DC Ø30 mm 55 14 1.2 29 3,500 24 Details
LWCD-30250LN-06 LWCD-30250LN-06DC Ø30 mm 67 14 1.32 32 3,500 12 Details
LWCD-30250MN-07 LWCD-30250MN-07DC Ø30 mm 67 14 1.44 32 3,500 24 Details
LWCD-30290LN-06 LWCD-30290LN-06DC Ø30 mm 85 15 1.44 33 2,400 12 Details
LWCD-30290MN-07 LWCD-30290MN-07DC Ø30 mm 85 15 1.68 33 2,400 24 Details
LWCD-30350LN-06 LWCD-30350LN-06DC Ø30 mm 105 16 1.56 34 2,400 12 Details
LWCD-30350MN-07 LWCD-30350MN-07DC Ø30 mm 105 16 1.92 34 2,400 24 Details
LWCD-30420LN-06 LWCD-30420LN-06DC Ø30 mm 125 17 1.68 34 2,400 12 Details
LWCD-30420MN-07 LWCD-30420MN-07DC Ø30 mm 125 17 2.16 34 2,400 24 Details
LWCD-30530MN-06 LWCD-30530MN-06DC Ø30 mm 137 17 2.88 32 2,400 24 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

Cross Flow Fans: 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure to 320 Pa, DC, AC and EC motors, across 236 series.

Cross flow (tangential) fans are specified by two numbers that both appear in the model code: impeller diameter and impeller length. LWCA-1501200 is a Ø150 mm impeller 1,200 mm long on an AC motor; LWCD is the 12 / 24 V DC line and LWCE the 230 V EC line. Diameters run from Ø30 to Ø150 mm and lengths from about 90 mm to 1,200 mm, all with aluminium-alloy impellers on maintenance-free ball bearings.

The discharge is a flat, even curtain as wide as the impeller, at low static pressure (8–320 Pa across the range). That makes the family the standard fan for indoor air-conditioner units, air curtains, elevator cabins, fireplaces and any appliance that needs a wide, quiet air stream from a slim housing.

How to select from this range

  1. Start from the housing: the impeller length must match the discharge opening, and the diameter is limited by the housing depth.
  2. Airflow scales almost linearly with length at a given diameter and speed, so a longer impeller at lower speed is the quiet way to reach a target airflow.
  3. Keep the air path open — cross flow fans develop little static pressure, so filters and grilles must be coarse.
  4. Pick the motor line by the appliance: LWCA for mains-powered units with two- or three-speed tapping, LWCD for battery or low-voltage designs with voltage / PWM control, LWCE for 230 V units that need stepless control and feedback.
  5. Confirm bearing side, shaft and lead-out position on the drawing; many combinations are made to order.

Where these fans are used

  • Indoor units of split and ducted air conditioners
  • Air curtains and door air barriers
  • Elevator cabin ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery-pack cooling

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cross Flow Fans

How do I read a cross flow fan model number?

LWCA-1501200SN-06: LWCA = AC line (LWCD = DC, LWCE = EC), 150 = impeller diameter in mm, 1200 = impeller length in mm, then the motor / mounting code and version. Compare models within the same diameter to trade length against speed.

What is the longest impeller you make?

Standard lengths in the catalogue reach 1,200 mm at Ø120–150 mm. Longer impellers are made with an intermediate bearing on request.

Can a cross flow fan work against a duct?

Only against very low resistance — typically below 100 Pa. For ducted duties choose an inline duct fan or a centrifugal blower; the selector will offer them if you enter a higher static pressure.

Which cross flow fans are ETL listed?

The DC cross flow line (LWCD, 12 / 24 / 48 V) is ETL listed under Intertek control no. 5022563 to UL 507 / CSA C22.2 No. 113. See the certificate scans on the R&D and certifications page.

Related selections

Scroll to Top
RFQ list