Cross Flow Fans

Filter by duty point318 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCD-60300LN-06 LWCD-60300LN-06DC Ø60 mm 207 34 9.6 41 2,000 12 Details
LWCD-60300MN-07 LWCD-60300MN-07DC Ø60 mm 207 34 11.04 41 2,000 24 Details
LWCD-60360LN-06 LWCD-60360LN-06DC Ø60 mm 240 34 11.4 42 2,000 12 Details
LWCD-60360MN-07 LWCD-60360MN-07DC Ø60 mm 240 34 12.24 42 2,000 24 Details
LWCD-60420LN-06 LWCD-60420LN-06DC Ø60 mm 355 35 1.32 43 2,000 12 Details
LWCD-60420MN-07 LWCD-60420MN-07DC Ø60 mm 355 35 12.72 43 2,000 24 Details
LWCD-60520MN-06 LWCD-60520MN-06DC Ø60 mm 414 28 24.9 45 1,800 24 Details
LWCD-60610MN-06 LWCD-60610MN-06DC Ø60 mm 486 29 26.4 46 1,800 24 Details
LWCD-60640MN-06 LWCD-60640MN-06DC Ø60 mm 510 29 27.12 47 1,800 24 Details
LWCD-60700MN-06 LWCD-60700MN-06DC Ø60 mm 558 30 28.08 47 1,800 24 Details
LWCD-60750MN-06 LWCD-60750MN-06DC Ø60 mm 597 31 28.8 48 1,800 24 Details
LWCD-60870MN-06 LWCD-60870MN-06DC Ø60 mm 693 32 30 50 1,800 24 Details
LWCD-651100MN-06 LWCD-651100MN-06DC Ø65 mm 1,178 58 100.8 55 1,800 24 Details
LWCD-65120LN-06 LWCD-65120LN-06DC Ø65 mm 143 40 15.6 47 1,800 12 Details
LWCD-65120MN-07 LWCD-65120MN-07DC Ø65 mm 143 40 12 47 1,800 24 Details
LWCD-651300MN-06 LWCD-651300MN-06DC Ø65 mm 1,392 58 100.8 55 1,800 24 Details
LWCD-65180LN-06 LWCD-65180LN-06DC Ø65 mm 214 41 18 47 1,800 12 Details
LWCD-65180MN-07 LWCD-65180MN-07DC Ø65 mm 214 41 14.4 47 1,800 24 Details
LWCD-65240LN-06 LWCD-65240LN-06DC Ø65 mm 286 42 20.4 48 1,800 12 Details
LWCD-65240MN-07 LWCD-65240MN-07DC Ø65 mm 286 42 16.8 48 1,800 24 Details
LWCD-65300LN-06 LWCD-65300LN-06DC Ø65 mm 357 42 21.6 49 1,800 12 Details
LWCD-65300MN-07 LWCD-65300MN-07DC Ø65 mm 357 42 357 49 1,800 24 Details
LWCD-65360LN-06 LWCD-65360LN-06DC Ø65 mm 429 43 22.8 50 1,800 12 Details
LWCD-65360MN-07 LWCD-65360MN-07DC Ø65 mm 429 43 19.2 50 1,800 24 Details
LWCD-65420LN-06 LWCD-65420LN-06DC Ø65 mm 500 44 24 52 1,800 12 Details
LWCD-65420MN-07 LWCD-65420MN-07DC Ø65 mm 500 44 21.6 52 1,800 24 Details
LWCD-65520LN-06 LWCD-65520LN-06DC Ø65 mm 606 52 32.4 53 1,800 12 Details
LWCD-65520MN-07 LWCD-65520MN-07DC Ø65 mm 606 52 28.8 53 1,800 24 Details
LWCD-65620LN-06 LWCD-65620LN-06DC Ø65 mm 722 53 30 53 1,800 12 Details
LWCD-65620MN-07 LWCD-65620MN-07DC Ø65 mm 722 53 38.4 53 1,800 24 Details
LWCD-65720LN-06 LWCD-65720LN-06DC Ø65 mm 819 55 31.2 53 1,800 12 Details
LWCD-65720MN-07 LWCD-65720MN-07DC Ø65 mm 819 55 31.2 53 1,800 24 Details
LWCD-65750LN-06 LWCD-65750LN-06DC Ø65 mm 853 56 33.6 54 1,800 12 Details
LWCD-65750MN-07 LWCD-65750MN-07DC Ø65 mm 853 56 39.6 54 1,800 24 Details
LWCD-65820LN-06 LWCD-65820LN-06DC Ø65 mm 933 56 36 55 1,800 12 Details
LWCD-65820MN-07 LWCD-65820MN-07DC Ø65 mm 933 56 36 55 1,800 24 Details
LWCD-65870LN-06 LWCD-65870LN-06DC Ø65 mm 990 58 38.4 55 1,800 12 Details
LWCD-65870MN-07 LWCD-65870MN-07DC Ø65 mm 990 58 38.4 55 1,800 24 Details
LWCD-80350MN-06 LWCD-80350MN-06DC Ø80 mm 465 39 13 53 1,500 24 Details
LWCD-80520MN-06 LWCD-80520MN-06DC Ø80 mm 650 59 23 54 1,500 24 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

Cross Flow Fans: 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure to 320 Pa, DC, AC and EC motors, across 236 series.

Cross flow (tangential) fans are specified by two numbers that both appear in the model code: impeller diameter and impeller length. LWCA-1501200 is a Ø150 mm impeller 1,200 mm long on an AC motor; LWCD is the 12 / 24 V DC line and LWCE the 230 V EC line. Diameters run from Ø30 to Ø150 mm and lengths from about 90 mm to 1,200 mm, all with aluminium-alloy impellers on maintenance-free ball bearings.

The discharge is a flat, even curtain as wide as the impeller, at low static pressure (8–320 Pa across the range). That makes the family the standard fan for indoor air-conditioner units, air curtains, elevator cabins, fireplaces and any appliance that needs a wide, quiet air stream from a slim housing.

How to select from this range

  1. Start from the housing: the impeller length must match the discharge opening, and the diameter is limited by the housing depth.
  2. Airflow scales almost linearly with length at a given diameter and speed, so a longer impeller at lower speed is the quiet way to reach a target airflow.
  3. Keep the air path open — cross flow fans develop little static pressure, so filters and grilles must be coarse.
  4. Pick the motor line by the appliance: LWCA for mains-powered units with two- or three-speed tapping, LWCD for battery or low-voltage designs with voltage / PWM control, LWCE for 230 V units that need stepless control and feedback.
  5. Confirm bearing side, shaft and lead-out position on the drawing; many combinations are made to order.

Where these fans are used

  • Indoor units of split and ducted air conditioners
  • Air curtains and door air barriers
  • Elevator cabin ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery-pack cooling

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cross Flow Fans

How do I read a cross flow fan model number?

LWCA-1501200SN-06: LWCA = AC line (LWCD = DC, LWCE = EC), 150 = impeller diameter in mm, 1200 = impeller length in mm, then the motor / mounting code and version. Compare models within the same diameter to trade length against speed.

What is the longest impeller you make?

Standard lengths in the catalogue reach 1,200 mm at Ø120–150 mm. Longer impellers are made with an intermediate bearing on request.

Can a cross flow fan work against a duct?

Only against very low resistance — typically below 100 Pa. For ducted duties choose an inline duct fan or a centrifugal blower; the selector will offer them if you enter a higher static pressure.

Which cross flow fans are ETL listed?

The DC cross flow line (LWCD, 12 / 24 / 48 V) is ETL listed under Intertek control no. 5022563 to UL 507 / CSA C22.2 No. 113. See the certificate scans on the R&D and certifications page.