Cross Flow Fans

Filter by duty point318 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCD-80620MN-06 LWCD-80620MN-06DC Ø80 mm 800 70 31 55 1,500 24 Details
LWCD-80720MN-06 LWCD-80720MN-06DC Ø80 mm 1,000 82 33 55 1,500 24 Details
LWCD-80820MN-06 LWCD-80820MN-06DC Ø80 mm 1,250 93 45 56 1,500 24 Details
LWCD-90360MN-06 LWCD-90360MN-06DC Ø90 mm 607 70 24.5 54 1,500 24 Details
LWCD-90520MN-06 LWCD-90520MN-06DC Ø90 mm 876 102 40 56 1,500 24 Details
LWCD-90680MN-06 LWCD-90680MN-06DC Ø90 mm 1,146 130 65 57 1,500 24 Details
LWCD-90800MN-06 LWCD-90800MN-06DC Ø90 mm 1,348 157 80 58 1,500 24 Details
LWCD-90930MN-06 LWCD-90930MN-06DC Ø90 mm 1,567 183 96 59 1,500 24 Details
LWCE-100380SN-06 LWCE-100380SN-06EC Ø100 mm 800 106 32 55 1,500 230 Details
LWCE-100520SN-06 LWCE-100520SN-06EC Ø100 mm 1,100 145 55 58 1,500 230 Details
LWCE-100620SN-06 LWCE-100620SN-06EC Ø100 mm 1,300 173 70 59 1,500 230 Details
LWCE-100720SN-06 LWCE-100720SN-06EC Ø100 mm 1,530 201 75 60 1,500 230 Details
LWCE-100820SN-06 LWCE-100820SN-06EC Ø100 mm 1,735 229 80 61 1,500 230 Details
LWCE-110380SN-06 LWCE-110380SN-06EC Ø110 mm 800 123 70 61 1,200 230 Details
LWCE-110520SN-06 LWCE-110520SN-06EC Ø110 mm 1,150 168 100 63 1,200 230 Details
LWCE-110620SN-06 LWCE-110620SN-06EC Ø110 mm 1,350 201 120 66 1,500 230 Details
LWCE-110720SN-06 LWCE-110720SN-06EC Ø110 mm 1,600 223 132 67 1,500 230 Details
LWCE-110820SN-06 LWCE-110820SN-06EC Ø110 mm 1,750 265 146 68 1,500 230 Details
LWCE-120380SN-06 LWCE-120380SN-06EC Ø120 mm 900 68 53 63 1,350 230 Details
LWCE-120560SN-06 LWCE-120560SN-06EC Ø120 mm 1,350 102 70 65 1,350 230 Details
LWCE-120680SN-06 LWCE-120680SN-06EC Ø120 mm 1,600 123 80 67 1,350 230 Details
LWCE-120780SN-06 LWCE-120780SN-06EC Ø120 mm 1,900 141 92 71 1,350 230 Details
LWCE-120900SN-06 LWCE-120900SN-06EC Ø120 mm 2,100 161 105 72 1,350 230 Details
LWCE-1501000SN-06 LWCE-1501000SN-06EC Ø150 mm 3,100 119 350 72 800 230 Details
LWCE-1501200SN-06 LWCE-1501200SN-06EC Ø150 mm 3,700 143 450 75 800 230 Details
LWCE-150380SN-06 LWCE-150380SN-06EC Ø150 mm 1,600 62 70 69 1,100 230 Details
LWCE-150500SN-06 LWCE-150500SN-06EC Ø150 mm 2,150 82 145 70 1,100 230 Details
LWCE-150700SN-06 LWCE-150700SN-06EC Ø150 mm 2,700 104 250 71 1,000 230 Details
LWCE-80350SN-06 LWCE-80350SN-06EC Ø80 mm 450 40 16 51 1,500 230 Details
LWCE-80520SN-06 LWCE-80520SN-06EC Ø80 mm 650 59 23 53 1,500 230 Details
LWCE-80620SN-06 LWCE-80620SN-06EC Ø80 mm 800 70 31 54 1,500 230 Details
LWCE-80720SN-06 LWCE-80720SN-06EC Ø80 mm 980 81 39 55 1,500 230 Details
LWCE-80820SN-06 LWCE-80820SN-06EC Ø80 mm 1,200 93 52 56 1,500 230 Details
LWCE-90360SN-06 LWCE-90360SN-06EC Ø90 mm 640 74 27 53 1,500 230 Details
LWCE-90520SN-06 LWCE-90520SN-06EC Ø90 mm 850 107 40 54 1,500 230 Details
LWCE-90680SN-06 LWCE-90680SN-06EC Ø90 mm 1,050 132 60 55 1,500 230 Details
LWCE-90800SN-06 LWCE-90800SN-06EC Ø90 mm 1,300 164 64 58 1,500 230 Details
LWCE-90930SN-06 LWCE-90930SN-06EC Ø90 mm 1,584 191 68.7 59 1,500 230 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

Cross Flow Fans: 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure to 320 Pa, DC, AC and EC motors, across 236 series.

Cross flow (tangential) fans are specified by two numbers that both appear in the model code: impeller diameter and impeller length. LWCA-1501200 is a Ø150 mm impeller 1,200 mm long on an AC motor; LWCD is the 12 / 24 V DC line and LWCE the 230 V EC line. Diameters run from Ø30 to Ø150 mm and lengths from about 90 mm to 1,200 mm, all with aluminium-alloy impellers on maintenance-free ball bearings.

The discharge is a flat, even curtain as wide as the impeller, at low static pressure (8–320 Pa across the range). That makes the family the standard fan for indoor air-conditioner units, air curtains, elevator cabins, fireplaces and any appliance that needs a wide, quiet air stream from a slim housing.

How to select from this range

  1. Start from the housing: the impeller length must match the discharge opening, and the diameter is limited by the housing depth.
  2. Airflow scales almost linearly with length at a given diameter and speed, so a longer impeller at lower speed is the quiet way to reach a target airflow.
  3. Keep the air path open — cross flow fans develop little static pressure, so filters and grilles must be coarse.
  4. Pick the motor line by the appliance: LWCA for mains-powered units with two- or three-speed tapping, LWCD for battery or low-voltage designs with voltage / PWM control, LWCE for 230 V units that need stepless control and feedback.
  5. Confirm bearing side, shaft and lead-out position on the drawing; many combinations are made to order.

Where these fans are used

  • Indoor units of split and ducted air conditioners
  • Air curtains and door air barriers
  • Elevator cabin ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery-pack cooling

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cross Flow Fans

How do I read a cross flow fan model number?

LWCA-1501200SN-06: LWCA = AC line (LWCD = DC, LWCE = EC), 150 = impeller diameter in mm, 1200 = impeller length in mm, then the motor / mounting code and version. Compare models within the same diameter to trade length against speed.

What is the longest impeller you make?

Standard lengths in the catalogue reach 1,200 mm at Ø120–150 mm. Longer impellers are made with an intermediate bearing on request.

Can a cross flow fan work against a duct?

Only against very low resistance — typically below 100 Pa. For ducted duties choose an inline duct fan or a centrifugal blower; the selector will offer them if you enter a higher static pressure.

Which cross flow fans are ETL listed?

The DC cross flow line (LWCD, 12 / 24 / 48 V) is ETL listed under Intertek control no. 5022563 to UL 507 / CSA C22.2 No. 113. See the certificate scans on the R&D and certifications page.

Related selections

Scroll to Top
RFQ list