LWFA-E-200-01 product photo
LWFA-E-200-01 product photo
  • ImpellerØ200 mm7.9 in
  • Max airflow1,000 m³/h589 CFM
  • Max static pressure305 Pa1.22 in. wg
  • Noise58 dB(A)

LWFA-E-200-01 LWFA Series Direct Drive Centrifugal Blower Ø200 mm

Ø200 mm | AC | Max airflow 1,000 m³/h | Max static pressure 305 Pa | 58 dB(A)

  • Factory direct
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 18-month warranty
  • CE · ETL · RoHS
View RFQ →

Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWFA-E-200-01 Dimensional drawing
Performance curve (P-Q)Static pressure vs. airflow. Curve numbers correspond to supply voltage / speed grades.
LWFA-E-200-01 Performance curve (P-Q)

Series catalogue

PDFLWFA LWFA Series Direct Driven centrifugal blower · 1.4 MB

Covers the whole series, not only this model.

Need a non-standard size or another format? Ask an engineer or search the download center.

LWFA-E-200-01 is a LONGWELL LWFA Series Direct Drive Centrifugal Blower from the Impeller Ø178–254 mm range, impeller Ø200 mm, maximum airflow 1,000 m³/h, maximum static pressure 305 Pa, noise 58 dB(A). The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.

Technical data

Model LWFA-E-200-01
Motor type AC
Max. airflow 1,000 m³/h
Max. static pressure 305 Pa
Noise 58 dB(A)
Impeller diameter Ø200 mm
Blade diameter 200mm

Typical applications

  • Commercial kitchen extraction
  • Ventilation units and AHUs
  • Process and fume extraction

Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.

Alternatives with the same impeller (Ø200 mm · AC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWFA-E-200-01 this model 1,000 m³/h305 Pa 58 dB(A)
LWA-200(8")U(S)M-01 23 m³/hsee curve 2,800 rpm135 W110-120 V View
LWDA-200 (8")U-MWN-01 720 m³/hsee curve 3,400 rpm179 W65 dB(A)110-120 V View
LWDA-200 (8")U-MWN-03 720 m³/hsee curve 3,400 rpm179 W61 dB(A)110-120 V View
LWDA-200(8")S-PWN-10 735 m³/h303 Pa 1,650 rpm113 W38 dB(A)230 V View
LWDA-200(8")U-PWN-12 750 m³/h302 Pa 1,950 rpm128 W38 dB(A)115 V View
LWDA-200(8")S-PWN-09 910 m³/h384 Pa 2,300 rpm130 W40 dB(A)230 V View
LWDA-200S-MBN-13 987 m³/h515 Pa 2,540 rpm176 W70 dB(A)230 V View
LWDA-200 (8")S-MWN-02 1,150 m³/hsee curve 2,900 rpm143 W59 dB(A)220-240 V View
LWDA-200 (8")S-MWN-04 1,150 m³/hsee curve 2,900 rpm143 W57 dB(A)220-240 V View
LWDA-200S-PWN-14 1,236 m³/h391 Pa 2,500 rpm130 W29 dB(A)230 V View
LWFA4E200-102NS-02 1,236 m³/h226.6 Pa 1,280 rpm330 W59 dB(A)230 V View
LWDA-200(8")U-PWN-11 1,250 m³/h435 Pa 2,480 rpm182 W41 dB(A)115 V View
LWA-200(8")U(S)M-02 1,300 m³/h140 Pa 2,800 rpm120 W110-120 V View
LWDA-200(8")S-MWN-08 1,300 m³/h140 Pa 2,800 rpm80 W62 dB(A)220 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.