Mixed Flow Fans

Mixed flow (diagonal) fans combine axial airflow with centrifugal pressure capability, suited to medium-resistance duct runs. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point32 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWDA-100 (4")S-PWN-02 LWDA-100 (4")S-PWN-02AC Ø100 mm 605 168 41 51 2,900 220-240 Details
LWDA-100 (4")U-PWN-01 LWDA-100 (4")U-PWN-01AC Ø100 mm 410 see curve 41 52 3,350 110-120 Details
LWDA-125 (5")S-PWN-02 LWDA-125 (5")S-PWN-02AC Ø125 mm 605 168 41 51 2,900 220-240 Details
LWDA-125 (5")U-PWN-01 LWDA-125 (5")U-PWN-01AC Ø125 mm 410 see curve 41 52 3,350 110-120 Details
LWDA-150 (6")S-MWN-02 LWDA-150 (6")S-MWN-02AC Ø150 mm 620 see curve 41 55 2,900 220-240 Details
LWDA-150 (6")U-MWN-01 LWDA-150 (6")U-MWN-01AC Ø150 mm 437 see curve 55 58 3,400 110-120 Details
LWDA-200 (8")S-MWN-02 LWDA-200 (8")S-MWN-02AC Ø200 mm 1,150 see curve 143 59 2,900 220-240 Details
LWDA-200 (8")U-MWN-01 LWDA-200 (8")U-MWN-01AC Ø200 mm 720 see curve 179 65 3,400 110-120 Details
LWDA-250 (10")S-MWN-02 LWDA-250 (10")S-MWN-02AC Ø250 mm 1,900 see curve 162 68 2,750 220-240 Details
LWDA-250 (10")U-MWN-01 LWDA-250 (10")U-MWN-01AC Ø250 mm 1,219 see curve 228 69 3,000 110-120 Details
LWDA-300 (12")S-MWN-02 LWDA-300 (12")S-MWN-02AC Ø300 mm 3,150 see curve 320 72 2,900 220-240 Details
LWDA-300 (12")U-MWN-01 LWDA-300 (12")U-MWN-01AC Ø300 mm 1,900 see curve 489 78 3,450 110-120 Details
LWDA-350 (14")S-MWN-02 LWDA-350 (14")S-MWN-02AC Ø350 mm 6,450 see curve 903 79 2,900 220-240 Details
LWDA-350 (14")U-MWN-01 LWDA-350 (14")U-MWN-01AC Ø350 mm 2,130 see curve 260 74 1,720 110-120 Details
LWDA-400 (16")S-MWN-02 LWDA-400 (16")S-MWN-02AC Ø400 mm 7,100 see curve 1,300 83 2,940 220-240 Details
LWDA-400 (16")U-MWN-01 LWDA-400 (16")U-MWN-01AC Ø400 mm 2,500 see curve 440 75 1,780 110-120 Details
LWDE-100 (4")S-PWN-02 LWDE-100 (4")S-PWN-02EC Ø100 mm 697 see curve 35 52 3,350 220-240 Details
LWDE-100 (4")U-PWN-01 LWDE-100 (4")U-PWN-01EC Ø100 mm 410 see curve 35 52 3,350 110-120 Details
LWDE-125 (5")S-PWN-02 LWDE-125 (5")S-PWN-02EC Ø125 mm 697 see curve 35 52 3,350 220-240 Details
LWDE-125 (5")U-PWN-01 LWDE-125 (5")U-PWN-01EC Ø125 mm 410 see curve 35 52 3,350 110-120 Details
LWDE-150 (6")S-MWN-02 LWDE-150 (6")S-MWN-02EC Ø150 mm 720 see curve 35 58 3,400 220-240 Details
LWDE-150 (6")U-MWN-01 LWDE-150 (6")U-MWN-01EC Ø150 mm 437 see curve 35 58 3,400 110-120 Details
LWDE-200 (8")S-MWN-02 LWDE-200 (8")S-MWN-02EC Ø200 mm 1,310 see curve 140 61 3,300 220-240 Details
LWDE-200 (8")U-MWN-01 LWDE-200 (8")U-MWN-01EC Ø200 mm 700 see curve 140 61 3,300 110-120 Details
LWDE-250 (10")S-MWN-02 LWDE-250 (10")S-MWN-02EC Ø250 mm 2,075 see curve 195 69 3,000 220-240 Details
LWDE-250 (10")U-MWN-01 LWDE-250 (10")U-MWN-01EC Ø250 mm 1,219 see curve 195 69 3,000 110-120 Details
LWDE-300 (12")S-MWN-02 LWDE-300 (12")S-MWN-02EC Ø300 mm 3,500 see curve 352 74 3,200 220-240 Details
LWDE-300 (12")U-MWN-01 LWDE-300 (12")U-MWN-01EC Ø300 mm 1,763 see curve 352 74 3,200 110-120 Details
LWDE-350 (14")S-MWN-02 LWDE-350 (14")S-MWN-02EC Ø350 mm 6,200 see curve 659 77 2,800 220-240 Details
LWDE-350 (14")U-MWN-01 LWDE-350 (14")U-MWN-01EC Ø350 mm 3,467 see curve 659 77 2,800 110-120 Details
LWDE-400 (16")S-MWN-02 LWDE-400 (16")S-MWN-02EC Ø400 mm 6,850 see curve 1,200 81 2,800 220-240 Details
LWDE-400 (16")U-MWN-01 LWDE-400 (16")U-MWN-01EC Ø400 mm 4,032 see curve 1,200 81 2,800 110-120 Details
Certifications for this product line
FCC ×2CE-LVD ×2CE-EMC
View certificates →

Mixed Flow Fans — selection guide

Mixed Flow Fans: 32 models, impellers Ø100–400 mm, maximum airflow 410–7,100 m³/h, static pressure to 168 Pa, AC and EC motors, across 16 series.

Mixed flow (diagonal) duct fans use an impeller between axial and centrifugal geometry: axial-style airflow with a centrifugal pressure component, in an inline casing from Ø100 to Ø400 mm (4 to 16 inch), 410–7,100 m³/h. Each size is offered as an AC pair (LWDA) and an EC pair (LWDE) in 110–120 V and 220–240 V, so the same fan is quoted for 60 Hz and 50 Hz markets. They are the choice for long runs, several bends or fine filters at a given duct size.

How to select from this range

  1. Choose mixed flow when a standard inline fan of the duct size cannot reach the pressure of the run.
  2. Select 110–120 V for North America, 220–240 V for Europe and Asia; both versions exist for every size.
  3. EC (LWDE) adds 0–10 V control for demand-controlled ventilation.

Where these fans are used

  • Long residential and office duct runs
  • Grow rooms with carbon filters
  • Booster duty behind filters
  • Workshop extraction

Curves marked “measured” come from our own test rigs per AMCA 210 / ISO 5801 methods; digitised catalogue curves are flagged as such in the selector — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Mixed Flow Fans

What sizes are the mixed flow fans?

Ø100, 125, 150, 200, 250, 300, 350 and 400 mm (4–16 inch), each in AC and EC, 110–120 V and 220–240 V — 32 models.

Mixed flow or ultra-silent for a bedroom?

Ultra-silent for the lowest sound level at short runs; mixed flow where the run is long and pressure decides. Both are listed with sound pressure in the data table.

Related selections

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
RFQ list