Industrial Axial Fans
Large-airflow axial fans for factories, workshops and industrial equipment, built for continuous operation and easy maintenance. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.
| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWA-200(8")U(S)M-02AC | Ø200 mm | 1,300 | 140 | 120 | — | 2,800 | 110-120 | Details |
![]() |
LWA-200S(T)M-03EAC | Ø190 mm | 1,500 | 250 | 150 | — | 2,800 | 220 | Details |
![]() |
LWA-250(10")U(S)M-03AC | Ø250 mm | 2,100 | 215 | 250 | — | 2,800 | 110-120 | Details |
![]() |
LWA-250S(T)M-04EAC | Ø240 mm | 2,700 | 300 | 250 | — | 2,800 | 220 | Details |
![]() |
LWA-300(12")U(S)M-04AC | Ø300 mm | 3,000 | 230 | 370 | — | 2,800 | 110-120 | Details |
![]() |
LWA-300S(T)M-05EAC | Ø290 mm | 3,720 | 300 | 370 | — | 2,800 | 220 | Details |
![]() |
LWA-350(14")U(S)M-04AC | Ø350 mm | 5,500 | 250 | 750 | — | 2,800 | 110-120 | Details |
![]() |
LWA-350S(T)M-05EAC | Ø340 mm | 4,840 | 550 | 550 | — | 2,800 | 220 | Details |
![]() |
LWA-400(16")U(S)M-04AC | Ø400 mm | 11,000 | 400 | 1,100 | — | 2,800 | 110-120 | Details |
![]() |
LWA-400S(T)M-05EAC | Ø390 mm | 5,860 | 750 | 900 | — | 2,800 | 220 | Details |
![]() |
LWA-450(18")U(S)M-01AC | Ø450 mm | 12,500 | 580 | 1,500 | — | 2,800 | 110-120 | Details |
![]() |
LWA-500S(T)M-03EAC | Ø490 mm | 6,800 | 185 | 750 | — | 1,450 | 220 | Details |
![]() |
LWA-600(24")U(S)M-03AC | Ø600 mm | 210 | see curve | 260 | 64 | 1,100 | 110-120 | Details |
![]() |
LWA-750(30")U(S)M-01AC | Ø750 mm | 260 | see curve | 420 | 68 | 1,100 | 110-120 | Details |
![]() |
LWA-900(36")U(S)M-01AC | Ø900 mm | 290 | see curve | 600 | 70 | 1,100 | 110-120 | Details |
![]() |
LWEA1000TM-171EAC | Ø1000 mm | 48,326 | 321 | 4,000 | — | 960 | 380 | Details |
![]() |
LWEA280S(T)M-155EAC | Ø280 mm | 1,605 | 60 | 180 | — | 1,450 | 220 | Details |
![]() |
LWEA280S(T)M-156EAC | Ø280 mm | 3,202 | 232 | 250 | — | 2,900 | 220 | Details |
![]() |
LWEA315S(T)M-157EAC | Ø315 mm | 2,273 | 74 | 250 | — | 1,450 | 220 | Details |
![]() |
LWEA315S(T)M-158EAC | Ø315 mm | 4,545 | 373 | 370 | — | 2,900 | 220 | Details |
![]() |
LWEA355S(T)M-159EAC | Ø355 mm | 3,265 | 93 | 370 | — | 1,450 | 220 | Details |
![]() |
LWEA355S(T)M-160EAC | Ø355 mm | 6,542 | 373 | 750 | — | 2,900 | 220 | Details |
![]() |
LWEA400S(T)M-161EAC | Ø400 mm | 4,687 | 119 | 550 | — | 1,450 | 220 | Details |
![]() |
LWEA400S(T)M-162EAC | Ø400 mm | 9,336 | 474 | 1,100 | — | 2,900 | 220 | Details |
![]() |
LWEA450S(T)M-163EAC | Ø450 mm | 6,658 | 150 | 550 | — | 1,450 | 220 | Details |
![]() |
LWEA500TM-164EAC | Ø500 mm | 9,133 | 185 | 750 | — | 1,450 | 380 | Details |
![]() |
LWEA560TM-165EAC | Ø560 mm | 12,812 | 232 | 1,100 | — | 1,450 | 380 | Details |
![]() |
LWEA560TM-166EAC | Ø560 mm | 8,471 | 110 | 1,100 | — | 960 | 380 | Details |
![]() |
LWEA630TM-167EAC | Ø630 mm | 18,250 | 294 | 1,500 | — | 1,450 | 380 | Details |
![]() |
LWEA710TM-168EAC | Ø710 mm | 26,120 | 373 | 3,000 | — | 1,450 | 380 | Details |
![]() |
LWEA800TM-169EAC | Ø800 mm | 37,370 | 474 | 4,000 | — | 1,450 | 380 | Details |
![]() |
LWEA800TM-170EAC | Ø800 mm | 24,739 | 208 | 2,200 | — | 960 | 380 | Details |
| LWWAF-3.2A-0.04-4P-1-001AC | — | 1,720 | see curve | 40 | — | 1,450 | 220 | Details | |
| LWWAF-3.2A-0.06-4P-1-002AC | — | 1,940 | see curve | 60 | — | 1,450 | 220 | Details | |
| LWWAF-3.2A-0.09-4P-1-003AC | — | 2,250 | see curve | 90 | — | 1,450 | 220 | Details | |
| LWWAF-3.6A-0.06-4P-1-001AC | — | 2,010 | see curve | 60 | — | 1,450 | 220 | Details | |
| LWWAF-3.6A-0.09-4P-1-002AC | — | 2,480 | see curve | 90 | — | 1,450 | 220 | Details | |
| LWWAF-3.6A-0.12-4P-1-003AC | — | 3,370 | see curve | 120 | — | 1,450 | 220 | Details | |
| LWWAF-4.5A-0.18-4P-1-001AC | — | 4,510 | see curve | 180 | — | 1,450 | 220 | Details | |
| LWWAF-4.5A-0.25-4P-1-002AC | — | 5,870 | see curve | 250 | — | 1,450 | 220 | Details |
Industrial Axial Fans — selection guide
Industrial Axial Fans: 58 models, impellers Ø190–1,000 mm, maximum airflow 210–48,326 m³/h, static pressure to 750 Pa, AC motors, across 12 series.
Industrial axial fans move very large volumes at low pressure: LWWAF wall fans (LWWAF-8A-1.5-6P = 8-size, 1.5 kW, 6-pole) and LWEA cased fans from Ø280 to Ø1,000 mm, 210 to 48,326 m³/h at 60–750 Pa with 40 W to 4 kW motors on 220 V, 380 V and 110–120 V. Built for continuous operation and simple maintenance in factories, workshops and process equipment.
How to select from this range
- Size by the required air-change rate and the louvre or shutter resistance; wall fans rarely see more than 100 Pa.
- The LWWAF code gives motor power and pole count directly; lower pole count means higher speed, pressure and noise.
- For ducted duties at higher pressure move to the tube axial line.
Where these fans are used
- Factory and workshop ventilation
- Warehouse and logistics halls
- Transformer and generator cooling
- Process equipment
Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — Industrial Axial Fans
What is the largest axial fan in the catalogue?
LWEA1000TM, a Ø1,000 mm cased fan delivering up to 48,326 m³/h; the LWWAF wall fans reach 4 kW.
Are industrial axial fans available for 60 Hz / 110–120 V?
Yes, 9 models in this line are listed for 110–120 V and most 220 V and 380 V sizes can be supplied for 60 Hz.