Axial Fans

Axial fans are most efficient in the high airflow / low-to-medium static pressure range: building ventilation, condensers and evaporators, heat-pump outdoor units, cooling towers and equipment cooling. AC / DC / EC motors, impellers Ø145–1000 mm. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point435 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWA-200(8")U(S)M-01 LWA-200(8")U(S)M-01AC Ø200 mm 23 see curve 135 2,800 110-120 Details
LWA-200(8")U(S)M-02 LWA-200(8")U(S)M-02AC Ø200 mm 1,300 140 120 2,800 110-120 Details
LWA-200S(T)M-03E LWA-200S(T)M-03EAC Ø190 mm 1,500 250 150 2,800 220 Details
LWA-250(10")U(S)M-01 LWA-250(10")U(S)M-01AC Ø250 mm 28 see curve 80 1,350 110-120 Details
LWA-250(10")U(S)M-02 LWA-250(10")U(S)M-02AC Ø250 mm 48 see curve 230 2,800 110-120 Details
LWA-250(10")U(S)M-03 LWA-250(10")U(S)M-03AC Ø250 mm 2,100 215 250 2,800 110-120 Details
LWA-250S(T)M-04E LWA-250S(T)M-04EAC Ø240 mm 2,700 300 250 2,800 220 Details
LWA-300(12")U(S)M-01 LWA-300(12")U(S)M-01AC Ø300 mm 35 see curve 100 1,350 110-120 Details
LWA-300(12")U(S)M-02 LWA-300(12")U(S)M-02AC Ø300 mm 46 see curve 120 1,350 110-120 Details
LWA-300(12")U(S)M-03 LWA-300(12")U(S)M-03AC Ø300 mm 65 see curve 370 2,800 110-120 Details
LWA-300(12")U(S)M-04 LWA-300(12")U(S)M-04AC Ø300 mm 3,000 230 370 2,800 110-120 Details
LWA-300S(T)M-05E LWA-300S(T)M-05EAC Ø290 mm 3,720 300 370 2,800 220 Details
LWA-350(14")U(S)M-01 LWA-350(14")U(S)M-01AC Ø350 mm 60 see curve 140 1,350 110-120 Details
LWA-350(14")U(S)M-02 LWA-350(14")U(S)M-02AC Ø350 mm 65 see curve 160 1,350 110-120 Details
LWA-350(14")U(S)M-03 LWA-350(14")U(S)M-03AC Ø350 mm 98 see curve 550 2,800 110-120 Details
LWA-350(14")U(S)M-04 LWA-350(14")U(S)M-04AC Ø350 mm 5,500 250 750 2,800 110-120 Details
LWA-350S(T)M-05E LWA-350S(T)M-05EAC Ø340 mm 4,840 550 550 2,800 220 Details
LWA-400(16")U(S)M-01 LWA-400(16")U(S)M-01AC Ø400 mm 90 see curve 170 1,350 110-120 Details
LWA-400(16")U(S)M-02 LWA-400(16")U(S)M-02AC Ø400 mm 110 see curve 200 1,350 110-120 Details
LWA-400(16")U(S)M-03 LWA-400(16")U(S)M-03AC Ø400 mm 150 see curve 750 2,800 110-120 Details
LWA-400(16")U(S)M-04 LWA-400(16")U(S)M-04AC Ø400 mm 11,000 400 1,100 2,800 110-120 Details
LWA-400S(T)M-05E LWA-400S(T)M-05EAC Ø390 mm 5,860 750 900 2,800 220 Details
LWA-450(18")U(S)M-01 LWA-450(18")U(S)M-01AC Ø450 mm 12,500 580 1,500 2,800 110-120 Details
LWA-500(20")U(S)M-01 LWA-500(20")U(S)M-01AC Ø500 mm 150 see curve 200 1,350 110-120 Details
LWA-500(20")U(S)M-02 LWA-500(20")U(S)M-02AC Ø500 mm 165 see curve 250 1,350 110-120 Details
LWA-500S(T)M-03E LWA-500S(T)M-03EAC Ø490 mm 6,800 185 750 1,450 220 Details
LWA-600(24")TM-02 LWA-600(24")TM-02AC Ø600 mm 310 see curve 800 1,350 380 Details
LWA-600(24")U(S)M-01 LWA-600(24")U(S)M-01AC Ø600 mm 205 see curve 500 1,350 110-120 Details
LWA-600(24")U(S)M-03 LWA-600(24")U(S)M-03AC Ø600 mm 210 see curve 260 64 1,100 110-120 Details
LWA-750(30")U(S)M-01 LWA-750(30")U(S)M-01AC Ø750 mm 260 see curve 420 68 1,100 110-120 Details
LWA-900(36")U(S)M-01 LWA-900(36")U(S)M-01AC Ø900 mm 290 see curve 600 70 1,100 110-120 Details
LWAA2D145S-5MNW-01 LWAA2D145S-5MNW-01AC Ø145 mm 268 see curve 50 46 2,800 380 Details
LWAA2D145S-5MNW-02 LWAA2D145S-5MNW-02AC Ø145 mm 309 see curve 35 49 3,200 380 Details
LWAA2D165S-5MNW-01 LWAA2D165S-5MNW-01AC Ø165 mm 278 see curve 50 47 2,800 380 Details
LWAA2D165S-5MNW-02 LWAA2D165S-5MNW-02AC Ø165 mm 330 see curve 35 50 3,200 380 Details
LWAA2D185S-7MNW-03 LWAA2D185S-7MNW-03AC Ø185 mm 670 see curve 55 51 2,400 380 Details
LWAA2D185S-7MNW-04 LWAA2D185S-7MNW-04AC Ø185 mm 742 see curve 75 52 2,700 380 Details
LWAA2D200S-7MEB-05 LWAA2D200S-7MEB-05AC Ø200 mm 906 see curve 65 53 2,300 380 Details
LWAA2D200S-7MEB-06 LWAA2D200S-7MEB-06AC Ø200 mm 1,009 see curve 70 55 2,400 380 Details
LWAA2D200S-7MKW-09 LWAA2D200S-7MKW-09AC Ø200 mm 906 see curve 65 58 2,300 380/400 Details
Certifications for this product line
RoHS
View certificates →

Axial Fans — selection guide

Axial Fans: 435 models, impellers Ø145–1,000 mm, maximum airflow 23–48,326 m³/h, static pressure to 3,690 Pa, AC, EC and DC motors, across 98 series. 96 of them carry a measured P-Q curve and 395 a dimensional drawing.

The axial range covers Ø145 to Ø1,000 mm in five lines that overlap in diameter but not in job. LWAA AC external-rotor fans (2-, 4-, 6- and 8-pole) are the fixed-speed workhorses for condensers and heat pumps; LWAE3G EC fans add speed control and part-load efficiency on the same mounting dimensions; LWAD3G DC fans serve 24 / 48 V and 310 V DC-bus equipment; LWWAF and LWEA industrial fans move very large volumes at low pressure in wall rings and casings; and LWMFAF / LWEAF tube axial fans handle higher pressures inside a duct.

Most models are IP54 with cold-rolled-steel or PA66 impellers, rated for −30 to +60 °C ambient (EC: −25 to +60 °C), on maintenance-free ball bearings. Three-phase 380 V and single-phase 220 / 230 V versions exist for nearly every size, and the largest EC fans (Ø500–900 mm) are three-phase.

How to select from this range

  1. Use the airflow at the coil or grille and the resistance it creates — a condenser coil and guard grille cost 30–80 Pa, which is a large share of an axial fan's pressure capability.
  2. Choose diameter for airflow and speed grade (pole count or EC speed setting) for pressure and noise; two adjacent diameters usually cover the same duty with 3–6 dB(A) difference.
  3. Stay on the falling, right-hand part of the curve. Left of the pressure peak an axial fan stalls and the noise rises sharply.
  4. For condenser pressure control, night set-back or redundancy choose EC (LWAE3G); for constant duty at lowest cost choose AC (LWAA).
  5. Match the mounting format — wall ring, guard grille, short case or long case — to the drawing before ordering; the same impeller is offered in several formats.

Where these fans are used

  • Condensers, evaporators and dry coolers
  • Heat-pump and chiller outdoor units
  • Cooling towers and transformer cooling
  • Factory and warehouse ventilation
  • Tunnel and agricultural ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Axial Fans

What static pressure can LONGWELL axial fans handle?

The LWAA / LWAE3G external-rotor fans are selected up to about 100–400 Pa depending on diameter and speed; the tube axial LWMFAF / LWEAF line reaches 750–3,690 Pa total pressure at the cost of noise. Above the external-rotor range the selector will usually offer a mixed flow or centrifugal alternative.

How do I read the LWAA model code?

LWAA4E400S-5MEW: 4 = poles, E = single-phase (D = three-phase), 400 = impeller diameter in mm, then the mounting and impeller code. So a 4-pole single-phase Ø400 mm fan. LWAE3G is the EC platform, LWAD3G the DC platform on the same numbering.

Which axial sizes are offered in EC?

LWAE3G runs from Ø200 to Ø900 mm: Ø200–450 mm on 220 / 230 V single-phase, Ø500–900 mm on 380 / 400 V three-phase, all with 0–10 V / PWM control and feedback, IP54 or IP55.

Do you have 60 Hz or 115 V axial fans?

The AC line is built for 50 Hz 230 / 380 V as standard and many sizes are available for 60 Hz; the industrial LWEA line is offered in 110–120 V. EC fans accept 50 / 60 Hz on the same model. Filter the category by voltage or ask for the variant you need.

Related selections

Scroll to Top
RFQ list